Combustion/ Secondary Air Control
Combustion
Air Control
Rear of
Appliance
Ignition Air Control
Ignition Air
Control
4. Refuelling the Appliance
Open the ignition air and combustion air controls fully
and burn for a few minutes before refuelling.
It is recommended that the door is not opened until only
embers are left in the combustion chamber. Opening the
door whilst flames are still burning, producing smoke and
gas, could cause smoke or flames to spill into the room.
Open the door slightly for a couple of seconds to
neutralise the negative pressure in the combustion
chamber before opening the door completely.
Rake the embers evenly over the fire bed to establish
a glowing firebed.
If the fire bed is low add a small amount of kindling
wood to help re-establish the fire and prevent excess
smoke.
Place 2 - 4 logs in a cross on top of the embers and
close the door.
Open stacking
Open stacking allows oxygen to easily reach every part of
the fire.
Compact stacking
Compact stacking will make the wood burn slower as
wood can only reach the outside of the fire. This will
cause the fire to smoulder and produce smoke.
Do not fill to more than 1/3 capacity.
Refuelling on to a low fire bed:
If there is insufficient burning material in the firebed to
light a new fuel charge, excessive smoke emission can
occur. Refuelling must be carried out onto a sufficient
quantity of glowing embers and ash that the new fuel
charge will ignite in a reasonable period. If there are too
few embers in the fire bed, add suitable kindling to
prevent excessive smoke.
Fuel overloading
The maximum amount of fuel specified in this manual
should not be exceeded, overloading can cause excess
smoke.
After refuelling:
Burn the new logs at high output for approximately 5
minutes before closing the ignition air control.
Adjust the burn rate using the combustion air control.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Varde Shape - Smoke Control Kit at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Varde Shape - Smoke Control Kit in the language / languages: English as an attachment in your email.

The manual is 0.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info