540880
77
Zoom out
Zoom in
Previous page
1/85
Next page
Vanguard
TM
Twin-Cylinder OHV Liquid-Cooled Engine
Section 6 - Final Adjustments & Specifications
Page 72
4. Tighten casing clamp screw.
Fig. 184
Choke Control Adjustment
1. Place choke control lever on equipment in
CHOKE
position.
2. Loosen control casing clamp screw.
3. Move control casing and wire until choke is
completely closed, Fig. 185.
4. Tighten casing clamp screw.
Fig. 185
CARBURETOR ADJUSTMENT
The VanguardE liquid cooled OHV Twin cylinder
carburetor fuel mixture adjustment procedure is unique.
Perform adjustments exactly in the sequence shown.
Initial Adjustment
1. Turn idle mixture screw for #1 cylinder clockwise
until it just seats. DO NOT FORCE.
2. Then turn screw counter-clockwise 3/4 turn, Fig
186.
3. Repeat for #2 cylinder.
This setting will permit engine to start. Final adjustment
will be made with engine running.
Fig. 186
1. When engine has been reassembled after any
major repairs, fill engine with a multi-viscosity oil
to the recommended level.
2. Then run engine for 5 minutes under NO belt
tension.
3. Then adjust belt tension to OEM specifications.
Final Adjustment
CAUTION: Failure to follow these instructions
may result in bearing seizure
IMPORTANT: Idle mixture adjustment must be
performed with the engine running at 1200 rpm.
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vanguard Twin Cylinder OHV Liquid-Cooled at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vanguard Twin Cylinder OHV Liquid-Cooled in the language / languages: English as an attachment in your email.

The manual is 7,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info