Twin-Cylinder OHV Liquid-Cooled Engine
Section 6 - Final Adjustments & Specifications
Page 71
SECTION 6
FINAL ADJUSTMENTS AND
SPECIFICATIONS
GENERAL INFORMATION
The purpose of the mechanical governor is to maintain,
within certain limits, a desired engine speed, even
though loads may vary. The governor spring tends to pull
the throttle open. The force of the flyweights, which are
operated by centrifugal force, tends to close the throttle.
The engine speed at which these two forces balance is
called the governed speed. The governed speed can be
varied by changing governor spring tension. If a
governor spring must be replaced, consult the
appropriate Illustrated Parts List. Select the proper
governor springs by engine type number.
NOTE: After a new governor spring is installed,
check engine top governed speed with an
accurate tachometer.
REMOTE GOVERNOR CONTROLS
VanguardE liquid cooled OHV Twin cylinder engines are
equipped for remote governor controls, Fig. 181.
Speed Regulation
Remote governor controls (supplied by equipment
manufacturer) control engine speed by increasing or
decreasing tension on governor spring(s) to obtain
desired engine speed at all positions.
Fig. 181
Governed Idle
VanguardE liquid cooled OHV Twin cylinder engines are
equipped with a governed idle system, Fig. 182. A
throttle restrictor permits the engine to maintain
engine speed when a load is applied with the equipment
control in the SLOW position.
Fig. 182
Remote Control Wire Travel
In order to make proper remote control adjustments, the
travel of the remote control wire must be
not less than 1-
3/8” (35 mm)
with controls mounted in equipment, Fig.
183.
Fig. 183
Speed Control Wire Adjustment
1. Loosen control casing clamp at governor control
bracket.
2. Move speed control lever to “FAST” position.
3. Move control casing and wire in direction shown
by arrow until governor control swivel is at end of
travel, Fig. 184.
2-1/8” MIN (54MM)
1-3/8” MIN. TRAVEL
(35MM)
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vanguard Twin Cylinder OHV Liquid-Cooled at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vanguard Twin Cylinder OHV Liquid-Cooled in the language / languages: English as an attachment in your email.

The manual is 7,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info