Figure 8 Radar Status Menu Control Section
Set the DEFAULT IRIS configuration so Radiate and Servo Power are o if
there is a possible hazard to personnel when IRIS starts.
CAUTION!
TASK Schedule
Determines which task schedule is run. Select the button to show a list of available task
schedules.
Ingest Process
Provides control and status for the software that runs the radar system and creates ingest
files. Toggle this button to start or stop radar operation.
In the Setup utility, you can
define whether RCP or signal processing (DSP) is reset when
ingest process starts up. By default resetting both is enabled.
Resetting RCP is a convenient way to reset after a shutdown. This also causes the RCP
reset output line to toggle, which may be configured to reset other equipment at the
radar site.
When the signal processor resets, it takes a noise sample before resuming data
collection. This is a convenient way to force a noise sample.
The text area to the right of the toggle button shows the ingest process status.
Table 9 Ingest Process Statuses
Status Description
Running The current task is running normally.
Idle No task is running, but the radar process is ready to run tasks. Either tasks have not been
scheduled, or it is not time for a scheduled task to run.
Stopped The ingest process is o.
Chapter 7 – Using the Radar Status Menu
37
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaisala IRIS Radar at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaisala IRIS Radar in the language / languages: English as an attachment in your email.

The manual is 5,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info