665292
36
Zoom out
Zoom in
Previous page
1/44
Next page
Appendix
36 Installation instructions 0020237057_00
C Connecting the actuators, sensors and sensor assignment for the VR 70 and VR
71
C.1 Legend for connecting the actuators and sensors
Legend
point
Meaning Legend
point
Meaning
9e Hot water generation diverter valve FSx Flow temperature sensor for heating circuit x
BH Auxiliary boiler 9kxcl Heating circuit mixer is closed for heating circuit x,
in combination with 9kxop
BufBt Lower cylinder temperature sensor in a buffer
cylinder
9kxop Heating circuit mixer is open for heating circuit x, in
combination with 9kxcl
BufBtDHW Bottom cylinder temperature sensor for hot water
generation in a buffer cylinder (MSS)
3fx Heating pump for heating circuit x
BufBtHC Top cylinder temperature sensor for the heating
circuit in a buffer cylinder (MSS)
3h Legionella protection pump
BufTopDHW Top cylinder temperature sensor for hot water
generation in a buffer cylinder (MSS)
LP/9e Charging pump or hot water generation diverter
valve
BufTopHC Bottom cylinder temperature sensor for the heating
circuit in a buffer cylinder (MSS)
MA Multi-function output
COL Collector temperature sensor PWM Control signal for the solar pump unit or the feed-
back signal
COLP Solar pump SysFlow System flow temperature (e.g. in low loss header)
CP Circulation pump TD2 Temperature difference sensor 2
DEMx Input for external requirement for heating circuit x 9g Diverter valve
DHW1 Cylinder temperature sensor ZoneOff 2-way valve for switching between zones, in com-
bination with Zone On
DHWBH Cylinder temperature sensor for the auxiliary
heater
ZoneOn 2-way valve for switching between zones, in com-
bination with Zone Off
DHWBt Lower cylinder temperature sensor 9bx Zone valve for Zone x
DHWoff 2-way valve for switching to cylinder, in combina-
tion with DHWon
Solar Yield Sensor for the solar yield, installed in the solar
circuit return. TD is used to calculate the solar
yield between the collector and return sensor
DHWon 2-way valve for switching to cylinder, in combina-
tion with DHWoff
eyield Sensor for more precise solar yield, installed in the
solar circuit flow. TD is used to calculate the solar
yield between the flow and return
C.2 Connecting the actuators and sensors to VR 70
Set value R1 R2 R3/R4 R5/R6 S1 S2 S3 S4 S5 S6 S7
1 3f1 3f2 MA 9k2op/
9k2cl
DHW1/
BufBt
DEM1 DEM2 SysFlow FS2
3 MA 3f2 LP/9e 9k2op/
9k2cl
BufTop
DHW
BufBt
DHW
BufBt
HC
SysFlow BufTop
HC
FS2
5 3f1 3f2 9k1op/
9k1cl
9k2op/
9k2cl
SysFlow DEM1 DEM2 FS1 FS2
6 COLP 3h MA 9b1 DHW1 DHWBt SysFlow COL Solar
Yield
PWM
12 COLP 3f1 9g/9e 9k1op/
9k1cl
Solar
Yield
DHWBt TD1 TD2 COL FS1 PWM
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRC 700F-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRC 700F-4 in the language / languages: English as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info