34 Installation instructions 0020237057_00
Setting level Values Unit Increment, select Default setting
Min. Max.
Solar flow volume 0.0 165.0 l/min 0.1
Solar pump boost off, On off
Solar circuit prot. 110 150 1 130
Min. collector temp 0 99 1 20
Purging time 0 600 min 10
Current flow rate 0.0 165.0 l/min 0.1
Solar cylinder 1 ----
Switch-on diff. 2 25 1 12
Switch-off diff. 1 20 1 5
Maximum temperature 0 99 1 75
Cyl. temp.: Bottom Current value
2nd temperature difference control ----
Switch-on diff. 1 20 1 5
Switch-off diff. 1 20 1 5
Minimum temperature 0 99 1 0
Maximum temperature 0 99 1 99
TD1 sensor Current value
TD2 sensor Current value
TD output off, On off
Ventilation ----
Air quality sensor 1 Current value ppm
Air quality sensor 2 Current value ppm
Air quality sensor 3 Current value ppm
Max. air qual. sensor 400 3000 ppm 100 1000
RF connection ----
Control reception 0 10 1
OT sensor reception 0 10 1
Installer level Sensor/actuator test
Unit No module, VR70 ad.1, VR71
Actuator No actuat., R1, to R12
Sensor No sensor, S1, to S13
Installer level HEATING1 Screed-drying function
Day 00 29 Day 1 00
Temperature Current value 1
Installer level Change code
New code 000 999 1 00
* If no fault is present, the status is No fault. If there is a fault, Fault list appears and you can read the fault message in the "Fault mes-
sages" section.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRC 700F-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRC 700F-4 in the language / languages: English as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info