3 Product description
6 Operating instructions ecoVIT exclusiv 0020258609_00
3 Control (accessory)
4 Main switch
5 + button
6 button
7 Reset button
8 Heating flow temperat-
ure rotary knob
9 Cylinder temperature
rotary knob
The display shows the current heating flow temperature, the
filling pressure of the heating installation, the operating mode
or certain additional information.
The i button is used to call up status information.
The control, which is available as an accessory, automatic-
ally controls the flow temperature depending on the outdoor
temperature.
The main switch is used to switch the product on and off.
The + button is used to display the cylinder temperature (if
the product is equipped with a cylinder temperature sensor).
The button is used to display the filling pressure of the
heating installation.
The Reset button is used to reset the product in the case of
certain faults.
The heating flow temperature rotary knob is used to set the
heating flow temperature if no control is connected. If a con-
trol is connected, the heating flow temperature rotary knob
should be turned clockwise as far as it will go.
The cylinder temperature rotary knob is used to set the cyl-
inder temperature if a domestic hot water cylinder is connec-
ted.
If a control is connected, the rotary knob should be turned
clockwise as far as it will go. The control then determines the
cylinder temperature.
3.3.1 Digital Information and Analysis System
(DIA)
1
2
1 Display showing the
current heating flow
temperature, the filling
pressure in the heating
installation, or a status
or fault code
2 Plain text display
3.3.2 Displayed symbols
Symbol Meaning Explanation
Fault in the air/flue gas
route
Fault in the air/flue gas
route
Symbol Meaning Explanation
comDIALOG The heating flow and do-
mestic hot water temper-
ature are specified via
the comDIALOG com-
munications system. The
product works at temper-
atures other than those
set at the rotary knob.
This operating mode can
only be terminated by:
comDIALOG
Changing the tem-
perature at the rotary
knobs by more than
± 5 K
This operating mode
cannot be terminated by:
Pressing the Reset
button.
Switching the
product off and on
again
Heating mode Symbol perman-
ently on: Product is
in heating mode op-
erating mode
Symbol flashing:
Burner anti-cycling
time is active
Hot water generation Symbol permanently
visible: Charging
mode for the do-
mestic hot water
cylinder is enabled
by the control and
floor-standing boiler
control system
Symbol flashes:
Domestic hot water
cylinder is being
heated
Heating pump operating
Solenoid valve is actu-
ated
Gas supply to the burner
is open
Current energy demand Display of the current
burner modulation rate
(bar graph display)
Fault during burner
operation
Burner is switched off
Burner operating cor-
rectly
Burner is switched on
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant ecoVIT exclusiv VKK 226-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant ecoVIT exclusiv VKK 226-4 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant ecoVIT exclusiv VKK 226-4

Vaillant ecoVIT exclusiv VKK 226-4 User Manual - German - 20 pages

Vaillant ecoVIT exclusiv VKK 226-4 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info