4 General Requirements
Instructions for installation and servicing aquaPLUS VUI 362-710
4.5.3 Flue termination
The following details refer to both flue systems.
a.The terminal must be positioned such that the
products of combustion can disperse freely at all
times.
b.In certain weather conditions a plume of water vapour
may be visible from the flue terminal. Positions where
this could be a nuisance should be avoided.
c. If the terminal is fitted less than 2 m above a balcony,
above ground or above a flat roof to which people
have access then a suitable terminal guard, Model K3,
must be provided and fitted (made by Tower Flue
Components, Tonbridge, TN9 1TB).
The flue assembly shall be so placed or shielded as to
prevent ignition or damage to any part of the building.
1) In addition, the terminal should not be nearer than 150 mm to an opening
in the building fabric formed for the purpose of accommodating a built-in
element such as a window.
* BS 5440-1 It is recommended that a fanned flue terminal should be
positioned as follows: a) at least 2 m from an opening in a building
directly opposite, and b) so that the products of combustion are not
directed to discharge across a boundary.
Note: Vertical flues must not terminate within 600 mm
of an openable window, air vent or any other ventilation
opening.
Fig. 4.4: Flue termination
A
BCD
A
G
H, I
F
J
B
F
M
L
L
K
K
G
G
F
F
E
A
A
Terminal position for fan-assisted flue mm
(minimum distance)
A
1)
Directly below an openable, above an opening or 300
horizontal to an opening i.e. air brick, opening
window or other , etc
B Below gutters, soil pipes or drain pipes 25
C Below eaves 25
D Below balconies (below car port roof) 25
E From vertical drain pipes and soil pipes 25
F From internal or external corners 25
G Above ground or balcony level 300
H From a surface or boundary facing a terminal 600*
I From a terminal facing a terminal 1200
J From an opening in a car port (e.g. door, window) 1200
into a dweling
K Vertically from a terminal on the same wall 1500
L Horizontally from a terminal on the same wall 300
M Distance from adjacent wall for vertical Flue 500
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aquaPLUS VUI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aquaPLUS VUI in the language / languages: English as an attachment in your email.

The manual is 3,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aquaPLUS VUI

Vaillant aquaPLUS VUI User Manual - English - 12 pages

Vaillant aquaPLUS VUI User Manual - English, German - 40 pages

Vaillant aquaPLUS VUI Manual - Dutch - 2 pages

Vaillant aquaPLUS VUI User Manual - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info