General Requirements 4
Instructions for installation and servicing aquaPLUS VUI 362-7 9
4.5 Flue system
4.5.1 Top outlet flue system (100 mm outside
diameter)
The top outlet horizontal flue system (Art. No. 303 807)
is suitable for installations up to 720 mm measured
from the centre of the boiler flue outlet to the outside
face of the wall.
Flue extensions are available to extend this length up to
3.2 m.
Both 90° bends and 45° elbows are also available to
increase siting flexibility.
A vertical flue system is also available (Art. No.
303 800).
Refer to flue system installation instructions for full
details.
Fig. 4.1: Art.-No. 303 807
Fig. 4.2: Art.-No. 303 800
48
1285
603
48
750
48
4
4.5.2 Extended top outlet flue system
(125 mm outside diameter)
A top outlet horizontal flue system of 125 mm outside
diameter is also available (Art. No. 303 609) and can be
used to achieve flue lengths of 10 m.
Both 45° and 90° bends and elbows are also available
to increase siting flexibility.
A vertical 125 mm concentric flue system is also
available (Art. No. 303 600).
Refer to flue system installation instructions for full
details.
Fig. 4.3: Art.-No. 303 609
70
1103
70
15
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aquaPLUS VUI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aquaPLUS VUI in the language / languages: English as an attachment in your email.

The manual is 3,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aquaPLUS VUI

Vaillant aquaPLUS VUI User Manual - English - 12 pages

Vaillant aquaPLUS VUI User Manual - English, German - 40 pages

Vaillant aquaPLUS VUI Manual - Dutch - 2 pages

Vaillant aquaPLUS VUI User Manual - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info