39
VIII Settings
VIII UWATEC
®
Aladin
®
dive computers
VIII
English
1 TEC Altitude adjustment
The altitude adjustment does not affect altitude ranges nor any calculations.
Adjust the altitude indication to your current altitude.
1. Starting from the time of day display push or until the
mountain symbol and the altitude appear.
2. Confirm that you wish to change the displayed altitude by pushing .
The altitude starts to flash.
3. Change the altitude in increments of 10 m / 50 feet by pushing or
.
4. Confirm the selected altitude with .
2 Menu
"
set 1
"
With menu
"
set 1
"
or SmartTRAK you can configure the following items (dive
functions):
Alarm depthStatus
Alarm time
Status
Starting from the time of day display push or until
"
set 1
"
appears.
Confirm that you wish to enter into the menu of
"
set 1
"
by pushing .
Once entered into the menu you can scroll with and through
the menu.
TEC Setting the depth alarm
1. Confirm that you wish to change the depth of the alarm or to switch it on
or off by pushing . The depth starts to flash.
2. Change the depth in increments of 5 m / 10 feet by pushing or
.
3. Confirm the selected depth with .
"
On
"
or
"
Off
"
starts to flash.
4.
"
On
"
indicates
"
activated
"
,
"
Off
"
indicates
"
deactivated
"
.
switches between
"
On
"
and
"
Off
"
.
Confirm the selected status with .
See also page 21.
TEC Setting the dive time alarm
1. Confirm that you wish to change the time of the dive time alarm or to switch
it on or off by pushing . The alarm time starts to flash.
2. Change the alarm time in increments of 5 minutes by pushing or
.
3. Confirm the selected alarm time with .
"
On
"
or
"
Off
"
starts to flash.
4.
"
On
"
indicates
"
activated
"
,
"
Off
"
indicates
"
deactivated
"
.
Switch between
"
on
"
or
"
off
"
by pressing .
Confirm the selected status with .
See also page 20.
Setting
• TEC Depth alarm
• TEC Dive time alarm
• TEC Safety stop duration
• TEC Maximum partial pressure of
oxygen (ppO
2 max
)
•
Time limit to reset the O
2
% mix to air
• Unit system
• TEC Water type
• TEC Backlight illumination duration
• Audible attention signals
• Water contacts
• Reset desaturation
Range
5 - 100 m (20 - 330 feet) on/off
5-195 min., on/off
1-5 min.
1.2-1.6 bar
no reset / 1 - 48 hrs.
metric/imperial
on (salt water) / off (fresh water)
2-12 sec.
on / off (SmartTRAK: selective)
on / off
on / off
Default /
Setting in
Aladin
®
PRIME
40m (130ft), off
60 min., off
3 minutes
1.4 bar
no reset
on (salt water)
6 sec.
on
on
no reset
Page
->39
->39
->40
->40
->40
->40
->40
->40
->41
->41
->41