4.9 Nitrogen loading bar graph
The nitrogen loading bar gives a graphical representation of how close to decompression you are. As you
absorb nitrogen during the dive, more and more segments of the bar will light up. Depending on your
depth, the segments can light up more or less rapidly.
** Depending on your profile, the no-stop time may drop below 3 minutes before the upper 5 segments
are lit. In this case, only those segments that are lit will flash.
If you have entered decompression, the 6
th
segment will turn off as soon as you complete your last decom-
pression obligation to indicate that you are no longer in decompression.
4.10 Decompression information
NO STOP and the no-stop time (minutes) are displayed if no decompression stops are necessary.
No-stop display <99:> means remaining time of 99 minutes or
more.
No-stop time is calculated on line and influenced by the current
water temperature
If no-stop time drops below 3 minutes, an audible
attention signal is activated, the no-stop value and
the nitrogen loading bar begin to flash.
If no-stop time is less than 1 minute, the no-stop
display shows the flashing value "0".
In order to prevent a decompression dive, ascend
slowly until the no-stop time is 5 minutes or more.
Dives that require decompression stops are not
recommended.
24
4 Functions during the dive
III UWATEC
®
Aladin
®
dive computers
No-stop time
Nitrogen loading bar
No-stop time less
than 1 minute
WARNING
WARNING
CNS O
2
%
DEPTHDEPTH
NO STNO STOPOP
DIVE DIVE TIMETIME
4 sec
Decompression values On entering the decompression phase, "NO STOP" disappears, the sym-
bol appears and an attention beep goes off. The nitrogen loading bar stops flas-
hing and the 6th segment lights up (red area). The deepest decompression
stage in metres (feet) is displayed and the decompression stop duration of the
displayed stage appears in minutes. The display <7: 3m (10ft)> means that a
decompression stop of 7 minutes at a depth of 3m (10ft) has to be made.
When a decompression stop has been finished, the next higher decompression
stop is displayed. When all decompression stops have been made, the
symbol extinguishes, "NO STOP" and no-stop time reappear.
Deco stop depths deeper than 27m (90 ft) are displayed as <– – : – – >
STOPSTOP
DECODECO
STOPSTOP
DECODECO
Decompression
depth
Decompression
stop duration
Decompression obligation
1-3 segments
(green area):
you are safely wit-
hin the no-stop
range
4-5 segments (yellow area):
you are approaching decom-
pression. When the no-stop
time drops below 3 minutes
the 5 segments will start
flashing.**
6 segments (red area): you now
have mandatory decompression
obligation(s) which you must
observe before reaching the
surface.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Aladin Tec at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Aladin Tec in the language / languages: English as an attachment in your email.

The manual is 1,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info