Changing the gas mixture
After immersion, Aladin automatically selects gas 1.
When during an ascent the switch depth is
reached (MOD gas D), an audible warning goes
off and "GAS d", its MOD and O
2
% blink for 30
seconds.
Procedure:
1. Switch to the regulator with gas D and start breathing.
2. Confirm the change by pressing
within 30 seconds. "GAS d" and the
oxygen fraction of gas D is displayed for 5 seconds without blinking.
To interrupt the switch process at any point, press
.
VI Diving with two gas mixtures
Switch depth
WARNING
S
L
O
W
NO
DEPTH
DIVE T IME
Switch to gas D
S
L
O
W
NO
DEPTH
DIVE T IME
Change to gas D confirmed
S
L
O
W
NO
DEPTH
DIVE T IME
4s
Switching process
initiated
Failed or inter-
rupted switch
S
L
O
W
NO
DEPTH
DIVE T IME
No change of gas mixture:
If a diver fails to confirm the change of gas mixture or interrupts the switching
procedure by pressing , Aladin displays "GAS 1", the MOD and the oxy-
gen fraction for 5 seconds. Aladin continues to calculate with gas 1 only and
adapts the decompression calculation accordingly.
If after the decompression calculation has readjusted itself to reflect
the failed switch the diver goes again below the switch depth (MOD
of gas D), Aladin will revert to the decompression calculation that
considers gas D also, since upon ascending again the diver will
have a renewed opportunity to perform the switch once the switch
depth is reached.
Belated change of gas mixture:
A diver can catch up on a required change to gas D until he reaches the sur
-
face.
1. Initiate the switching process by pressing . Aladin displays "GAS d", MOD
and the oxygen fraction of gas D blinking for 30 seconds.
2. Switch to the regulator with the deco gas mixture and start breathing.
3. Confirm the change by pressing
. "GAS d" and the oxygen fraction of
the deco gas is displayed for 5 seconds without blinking. The decompression
calculation will readjust accordingly. (Press to interrupt the switch process
at any time.)
Submerging again after a change to gas D:
If after a change to gas D the Maximum Operating Depth (MOD) of gas D is
exceeded, the ppO
2
max warning will appear ->25.
Change back to gas 1, which is suited for this depth, or rise to the Maximum
Operating Depth of gas D. Failure to do so can result in oxygen poisoning.
1. Initiate the switching process by pressing . Aladin displays "GAS 1", MOD
and the oxygen fraction of gas 1 for 30 seconds.
2. Switch to the regulator with gas 1 and start breathing.
3.
C
onfirm the change by pressing . "GAS 1" and the oxygen fraction of
gas
1
is displayed for 5 seconds without blinking. Afterwards the decompres-
sion calculation will readjust accordingly.
4s
MOD gas d
VI UWATEC Aladin TEC 2G
MOD gas 1
MOD gas d
40
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Aladin TEC 2G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Aladin TEC 2G in the language / languages: English as an attachment in your email.

The manual is 6,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Aladin TEC 2G

UWATEC Aladin TEC 2G User Manual - German - 54 pages

UWATEC Aladin TEC 2G User Manual - Dutch - 54 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info