550273
38
Zoom out
Zoom in
Previous page
1/54
Next page
Alternate displays during a dive with two gases
All displays time out after 5 seconds and the default display is shown again.
(Only exception is the temperature, screen 2 below.)
1
The default display shows the predictive decompression prognosis, which assumes the diver will
switch to the deco gas at the specified switch depth. In the bottom left corner the temperature is
displayed unless the current depth is 1m/3ft shallower than the max depth, in which case the max
depth is displayed.
2
Upon pressing the right button, the temperature and the current O
2
% are shown in the lower row.
O
2
% will time out after 5 sec while the temperature remains.
3
Upon pressing the right button, "GAS 1" or "GAS d" appears in the middle row to indicate the cur
-
rently active gas and the MOD appears in the bottom left corner. "GAS 1" or "GAS d" will time out
after 5 seconds unless the right button is pressed again.
4
In case that gas 1 is the active gas, pressing the right button one more time shows O
2
% of gas 1 in
the bottom right corner and the decompression information in case the deco gas is not used (decom-
pression information relative to gas 1 only). This is the calculation that Aladin would switch to in case,
having reached the switch depth, the diver did not confirm the switch. The decompression information
and the O
2
% blink.
5
If an MB level greater than L0 is active, pressing the right button one more time shows the predictive
decompression information and in the bottom left corner the currently active MB level.
6
Pressing the right button again shows the predictive decompression information relative to L0 togeth
-
er with the L0 symbol at the bottom left.
7
One more right button push shows the decompression information relative to L0 if only gas 1 is used,
with the decompression information and the O
2
% of gas 1 blinking.
8
Upon pressing the right button again, the time of day appears in the middle row.
The time to reset the
O
2
% mix to air can be set with SmartTRAK between
1 hour and 48 hours or to "no reset" (default).
After the reset, the oxygen fraction of gas 1 is set to 21% and gas D is set to
"– – O
2
%" (single gas dive).
Switching between single-gas and two-gas diving
If gas D is not going to be used during the next dive you can either set it to
"– O
2
%" (->37, point 2) or you can turn off the deco gas option in SET 1.
When you turn off the deco gas option in SET 1, the setting in the GAS D O
2
menu remains but Aladin calculates the dive using gas 1 only.
If the deco gas option is turned off, the GAS D O
2
menu will display OFF in the
lower left corner (instead of an MOD) and the ppO
2
setting will not appear.
VI Diving with two gas mixtures
Predictive decompression prognosis
The calculation of decompression data is based on the assumption that the change of gas mixture will be
performed at the previously selected switch depth (MOD gas D). If a diver ignores the required change or
changes the mixture belatedly, Aladin will readjust the decompression calculation accordingly. In case of
an ignored switch the dive computer will then base its calculations on the assumption that the diver will
ascend to the surface with gas 1.
WARNING
Functions during a dive with two gas mixtures
Diving with more than one gas mixture represents a much higher risk than
diving with a single mixture, and mistakes by the diver may lead to serious
injury or death.
During dives with several gas mixtures, always make sure you are breathing from the tank you intended
to breath from. Mark all your tanks and regulators, so they can under no circumstances be mixed up!
Before every dive and after changing a tank, make sure that each gas mixture is set to the correct value
for the corresponding tank.
VI UWATEC Aladin TEC 2G
38
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Aladin TEC 2G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Aladin TEC 2G in the language / languages: English as an attachment in your email.

The manual is 6,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Aladin TEC 2G

UWATEC Aladin TEC 2G User Manual - German - 54 pages

UWATEC Aladin TEC 2G User Manual - Dutch - 54 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info