Safety considerations
I UWATEC Aladin TEC 2G
You must carefully read and understand this entire manual before using your
Aladin
TEC 2G
.
Diving has many inherent risks. Even if you follow the instructions of this
manual in a careful manner, it is still possible that you may be seriously injured
or die from decompression sickness, oxygen toxicity or some other inherent
risk of scuba with Nitrox or compressed air. Unless you are fully aware of these
risks and are willing to personally accept and assume responsibility for those
risks, do not use
Aladin
TEC 2G
.
Guidelines for the use of Aladin TEC 2G:
The following guidelines for using Aladin
TEC 2G
are derived from the latest medical research and the
recommendations of the American Academy of Underwater Sciences for diving with diving comput-
ers. Following these guidelines will greatly increase your safety while diving, but cannot guarantee that
decompression sickness or oxygen toxicity will not occur.
Aladin
TEC 2G
is designed for dives with compressed air (21% O
2
) and Nitrox (22 to 100% O
2
) only. Do
not use Aladin
TEC 2G
for dives made with other mixed gases.
It is absolutely necessary to check the set mixture before each dive and to compare it to the gas
mixture currently used. Always remember: setting an incorrect mixture carries an inherent risk of
decompression sickness and/or oxygen toxicity! Maximum deviation from the measured mixture must
not exceed 1%O
2
. An incorrect gas mixture can be lethal!
Only use Aladin
TEC 2G
with open circuit breathing systems.
Only use Aladin
TEC 2G
for diving with an independent breathing apparatus. Aladin
TEC 2G is not
designed for long term exposures with Nitrox.
Always observe the visual and audible alarm signals. Avoid situations of increased risk which are
marked with a warning sign in this operating manual.
Aladin
TEC 2G
has a ppO
2
warning. The default limit is set at 1.4bar ppO
2
max. It can be changed
between 1.2 and 1.6bar.
Frequently check the "oxygen clock" (CNS O
2
). Ascend and finish the dive if the CNS O
2
exceeds
75%.
Never dive deeper than the Maximum Operating Depth (MOD) pertinent to the gas mixture in use.
Always check the diving limits considering the oxygen content and standard sports diving procedures
(decompression sickness, oxygen toxicity).
In accordance with the recommended maximum diving limit of all instructional agencies, do not dive
deeper than 40 metres/130 feet.
The danger of nitrogen narcosis has to be taken into consideration
. Aladin
TEC 2G
gives no warning
about this.
On all dives, with or without dive computer, make a safety stop for at least 3 minutes at 5 metres (15 feet).
All divers using dive computers to plan dives and indicate or determine decompression status must
use their own computer, which they take with them on all dives.
If Aladin
TEC 2G
fails at any time during the dive, the dive must be terminated, and appropriate surfac-
ing procedures (including a slow ascent and a 3 to 5 minute safety stop at 5
metres /15 feet
) should
be initiated immediately.
Comply with the ascent rate and carry out any decompression stop required. If the computer should
fail for any reason, you must ascend at a rate of 10m (30ft) per minute or less.
On any given dive, both divers in a buddy pair must follow the most conservative dive computer for
that particular dive.
Never dive without a buddy. Aladin
TEC 2G
does not substitute for a dive buddy.
Only make dives that are appropriate to your level of dive training. Aladin
TEC 2G
does not increase
your knowledge of diving.
Always dive with back-up instruments. Make sure that you always use back-up instrumentation
including a depth gauge, submersible pressure gauge, digital bottom timer or dive watch, and have
access to decompression tables whenever diving with a dive computer.
Avoid repeated ascents and descents (yo yo diving).
WARNING
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Aladin TEC 2G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Aladin TEC 2G in the language / languages: English as an attachment in your email.

The manual is 6,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Aladin TEC 2G

UWATEC Aladin TEC 2G User Manual - German - 54 pages

UWATEC Aladin TEC 2G User Manual - Dutch - 54 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info