550269
93
Zoom out
Zoom in
Previous page
1/104
Next page
93
VII Uwatec
®
Aladin
®
Air Z O
2
English
VII
possible reason(s) possible reason(s)
symptom
VII Trouble Shooting
Displayed tank pres-
sure does not corres-
pond to pressure mea-
sured by a manometer
(depth gauge).
The logbook does
not show any gas mix-
ture consumption (dp)
for a certain dive.
Altitude section does
not correspond to the
current altitude.
By compensating for temperature, the
pressure displayed is valid at 20 °C.
If the gas or water temperature differ
from this value, a difference to the
value given by a manometer is pos-
sible.
Tank and transmitter do not have the
same temperature (only possible in
air).
Manometer/depth gauge is not accu-
rate (temperature 20 °C).
No tank pressure signal was received
at the beginning or end of the dive.
Transmitter and dive computer were
not paired before the dive started.
The dive has been made with an Oxy2.
Atmospheric pressure is especially
high or low.
Ambient air pressure measured by
the computer is wrong.
Make comparison at 20 °C or check
the tank pressure compensated to
the atmospheric pressure for compa-
rison (see page 98).
Leave the tank with the regulator
mounted and the gas mixture turned
on for five to ten minutes.
Measure tank pressure with another
manometer/depth gauge (at 20 °C).
Mount transmitter correctly
(see page 35).
Pair transmitter and computer
(see page 40).
Check barometric information.
Send in dive computer for servicing
(only if altitude section is wrong by
more than one section, see page 70).
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Aladin Air Z O2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Aladin Air Z O2 in the language / languages: English as an attachment in your email.

The manual is 1,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Aladin Air Z O2

UWATEC Aladin Air Z O2 User Manual - German - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info