No reception of the tank
pressure-/oxygen data
Bad reception of tank
pressure or Oxy2 data.
/ and computer are not tuned
to each other (paired)
/ or receiver in the computer
are defective.
Oxy2 switch in position „CAL“.
In surface-mode if there is no
decrease in pressure the data will not
display (see page 20).
Automatic switches itself off after
interval at surface (see page 21).
/
is not mounted correctly.
/
or receiver in the computer is
defective.
/ Pair transmitter and computer
(see page 38-40).
If pairing is not possible with another
/ the receiver in the computer
is defective. Have dive computer
repaired.
Turn switch to „RUN“.
Change the pressure by breathing
from the regulator. Data will appear.
Switch on manually.
Mount / correctly
(see page 34/35).
If pairing is not possible with another
/ the receiver in the computer
is defective. Have dive computer
repaired.
92
VII Trouble Shooting
VII Uwatec
®
Aladin
®
Air Z O
2
possible reason(s) response
symptom