Note: To switch ID Scan or ID Search, press and hold
TRUNK or, press SCAN or SEARCH while scanning.
Multi-Track Operational Details
When more than one trunk system is active (for example two
or more trunked systems or a trunked system and one or
more conventional frequencies), the radio jumps between
systems/frequencies as follows:
TRUNK SCAN: The scanner moves to a trunked system
and looks for IDs in your Scan List(s) for up to 1 second.
If it finds no activity on your programmed talkgroups, it
moves on to conventional channels in the same bank or to
the next active bank.
If the scanner finds that a talkgroup in one of your active
Scan Lists becomes active, you will begin to hear that
communication and the scanner will display the proper
talkgroup number and any alpha tag. When the
communication ends, the scanner will wait for 2 seconds
for any further replies and, if none, the scanner will move
to the conventional channels in the same bank or to the
next bank. The scanner will not look for any other IDs
within the same trunked system (as this would slow the
scan process). If you press RSM while you are listening to
one ID, the scanner will check to see if another ID in your
Scan List is active. It will disregard the ID to which you
were just monitoring.
TRUNK SEARCH: This mode works similarly to Trunk
Scan. If the scanner finds any (non-locked-out) ID when
it checks the control channel, you will hear it. You will then
hear any replies that follow within 2 seconds. After that the
scanner will move on and not continuously search the
system for additional IDs (on busy systems you would never
leave the system if this were the case). If you press the
RSM key while monitoring one ID, the radio will check if any
other IDs are active (it will disregard the ID you just left),
and if none are active, it will move on.
48
BC296D(NEW) 10/16/03 6:35 PM Page 48
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Uniden BC296D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Uniden BC296D in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info