Installation info
2.3 WIRING DIAGRAM
2.3.1 ACTUAL WIRING DIAGRAM
fig. 25
LEGENDA
A1...A8 = Connectors
TA = Room thermostat (optional)
VG = Gas valve
RIV/AC = Ignition/Ionisation electrode
V = Fan (only for TFS)
PV = Fan pressure switch (only for TFS)
TL = H.L. Thermostat
TF = Flue-gas spillage thermostat
P = Circulating pump
DK = Minimum water pressure switch
SR = C.H. sensor
FL = Flow switch
SS = Rotary flow switch (only for CTN-CTFS)
MVD = Motor 3 way valve (optional for only heating boiler).
MD = Modulating coil
MD – MODULATING COIL
DK – MINIMUM WATER PRESSURE
SR – C.H. TEMPERATURE SENSOR
TA – ROOM THERMOSTAT
TF – FLUE GAS SPILLAGE THERMOSTAT
TL – HIGH LIMIT THERMOSTAT
PV – FAN PRESSURE SWITCH
TL HIGH LIMIT THERMOSTAT
FL = Flow switch
SS = DHW sensor
MDVMOTOR 3
WAY VALVEGREEN
V – FAN
MAIN SUPPLY
230V-50HZ
P – PUMP
IONISATION
IGNITION ELECTROD
GAS VALVE
- 1/4 W
27


Need help? Post your question in this forum.

Forumrules
1

Forum

unical-eve-05-ctfs-24

Reset search

  • LA CALDAIA MI DA ERRORE 6C, MA NON SUCCEDE NULLA SE PREMO IL RIPRISTINO O RESET, CHE COSA PUO' ESSERE.?
    GRAZIE A TUTTI Submitted on 28-5-2022 at 19:02

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unical EVE 05 CTFS 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unical EVE 05 CTFS 24 in the language / languages: English as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info