4
ULGD 3.8 A1
GB
IE
Operation
Before use
Before connecting the charger, the operating
instructions must be observed.
Furthermore, the instructions of the vehicle man-
ufacturer regar
ding a permanently connected
vehicle battery must be observed. Secure the
vehicle, switch off the ignition.
Clean the battery poles. Take care that while
doing so, your ey
es do not come into contact
with the dirt.
Ensure suffi cient ventilation.
Connecting
Before starting the charging or trickle charging
procedure on a permanently installed battery in
a vehicle, fi rst disconnect the negative terminal
connecting cable (black) of the vehicle from the
negative terminal of the battery. The negative
terminal of the battery is usually connected to
the vehicle’s coachwork.
Connect the positive pole clamp (red)
of the
charger to the positive pole of the battery.
Connect the negative pole clamp (black)
to the
negative pole of the battery.
Connect the mains cable
of the charger to
the mains socket.
The battery voltage display
shows the cur-
rent battery voltage.
Should the connection of the clamps be
swapped, the LED „re
verse connection“
lights up.
Disconnect
Disconnect the appliance from the mains supply.
Remove the negative pole clamp (black)
from
the negative pole of the battery.
Remove the positive pole clamp (red)
from
the positive pole of the battery.
Measuring STANDBY /
Battery voltage
After connection to the grid, the appliance is on
STANDBY. The standby display lights up. When
the clamps are connected, the battery voltage is
shown in the LCD (voltage display
). The segments
of the condition display are empty.
If the voltage is below 3.8 V or above 15 V, the
battery will not be charged. The display briefl y
shows the error message „Err“.
The appliance goes on standby.
6 V battery:
If the voltage range of the battery is measured
as between 3.7–7.3 V, only program 1 can be
selected.
12 V batteries:
If a battery is recognised in the critical voltage
range of between 7.3–10.5 V, the appliance
checks whether a fully charged 6 V battery, or a
discharged 12 V battery is present. After pressing
the program selection button
to select a program,
the appliance carries out a control measurement
for about 90 sec.
The display shows:
If after about 90 sec. between 7.3–7.5 V are
detected, the 12 V battery is defective.
The appliance goes on standby.
Revitalising
If after about 90 sec. between 7.5–10.5 V are
detected, a 12 V battery is present.
Charging starts with a pulse charge for revitalis-
ing. The voltage display
ashes. Once 10.5 V
are reached, the appliance switches to the other
charge steps.
Revitalising is the same for all the 12 V charge
programmes.
IB_102626_ULGD3.8A1_FI_SE_DK_BE_NL.indb 4 06.08.14 08:48
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ultimate speed ULGD 3.8 A1 - IAN 102626 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ultimate speed ULGD 3.8 A1 - IAN 102626 in the language / languages: English, German, Dutch, Danish, French, Swedish, Finnish as an attachment in your email.

The manual is 2,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info