606437
39
Zoom out
Zoom in
Previous page
1/44
Next page
39 GB
Safety notices / Operation
Operation
connect the battery‘s negative terminal connec-
tion cable (black) from the negative battery ter-
minal. The negative battery terminal is typically
connected to the car body.
Then disconnect the vehicle‘s positive terminal
connection cable (red) from the positive battery
terminal.
Only then connect the battery charger‘s “+“
crocodile clamp (red)
7
to the “+“ battery
terminal.
Connect the “-“ crocodile clamp (black)
6
to
the “–“ battery terminal. Plug the car charger‘s
mains cable
9
into the mains socket.
Note: If the connector clamps are correctly connect-
ed, the display will show the voltage and “connect-
ed“ will light up. If the poles are reversed, the displ
ay
will read 0.0 and “connected“ will not light up.
Disconnecting
Disconnect the device from the mains.
Remove the “–“ crocodile clamp (black)
6
from
the “–“ battery terminal.
Remove the “+“ crocodile clamp (red)
7
from
the “+“ battery terminal.
Reconnect the vehicle‘s positive connection cable
to the positive battery terminal.
R
econnect the vehicle‘s negative connection cab
le
to the negative battery terminal.
Selecting the charging mode
You can charge a variety of batteries at different
ambient temperatures using different charging mo
des.
Compared to conventional car chargers, this device
features a special function for reusing a drained bat-
tery / rechargeable battery. You can recharge a
completely drained battery / rechargeable battery.
The safe charging process protects against faulty co
n-
nection and short-circuits. The integrated electronics
do not switch the car charger on immediately after
being connected, but only after selecting a charging
mode.
If the connector clamps connected to the battery
and the device is connected to power, the digital
display
10
will read “Connected“. After selecting a
charging mode, the display will read “Charging“.
Once charging is complete, the display will read
“Charged“.
A continuously lit display with the battery not yet fully
charged indicate a fault.
In this event, verify the connection clamps
6
,
7
are correctly connected to the battery and
the correct battery type is selected. If the display
is still continuously lit, the battery may be de-
fective.
Digital Display button
1
: Use to switch be-
tween the digital display of voltage and charging
progress in percent (Battery %). Use this button to
switch between the following displays:
Battery %: indicates the charging progress for
the connected battery in percent.
Voltage: indicates the voltage of the connected
battery.
Alternator %: output power in percent
Battery Type button
2
: Use this button to set
the battery type to be charged. You can choose from
battery types. The battery type must absolutely be
correctly selected before starting the charging pro-
cess:
12 V Regular: these batteries (lead-acid batteries
)
are typically used in cars, lorries and motorcycles.
They have vent caps and are often labelled
“low-maintenance“ or “maintenance-free“. This
battery type is designed to quickly transfer ener-
gy (e.g. starting an engine). “Regular“ batteries
should not be used for “Deep Cycle“ applica-
tions.
12 V Deep Cycle: These batteries are commonly
also labelled “Deep Cycle“ or “Marine“. This
type of battery is typically larger than other
battery types. It delivers less short-term energy
but transmit energy longer. These batteries with-
stand numerous discharge cycles.
12 V AGM / Gel: The AGM battery type is typi-
cally a good Deep Cycle battery. They provide
100683_uls_Kfz-Ladegeraet mit Starthilfefunktion ULG 12 A1_content_CH.indd 39 19.09.14 15:13
39


Need help? Post your question in this forum.

Forumrules
1

Forum

ultimate-speed-ulg-12-a1---ian-100683

Reset search

  • I need a part for a parkside gasless welder IAN 291492 can you please Help phone No 07980041407 . email
    john.hutchings73@ntlworld.com
    Thanks
    John Hutchings Submitted on 5-7-2021 at 17:15

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ultimate speed ULG 12 A1 - IAN 100683 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ultimate speed ULG 12 A1 - IAN 100683 in the language / languages: French, Italian as an attachment in your email.

The manual is 2,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ultimate speed ULG 12 A1 - IAN 100683

Ultimate speed ULG 12 A1 - IAN 100683 User Manual - English, German, Dutch, Swedish - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info