combustion efficiency, draft, flue gas temperature etc. This analysis should also be made in writing in the two
forms that you find at the end of this manual. One of them you keep and one should be sent to ULMA AB in
Svenljunga. If this is not followed the warranty part of the burner is not valid.
Goal values:
CO2 : 11 %
CO :10 - 300 ppm
O2 : 8 10 %
hPa : -0,10 / -0,15 (draft)
Combustion efficiency (average): 90-92 %
Fuel quality
The burner can handle most kinds of wood pellets between 6-8mm. At change of pellet deliverer the burner
should be adjusted with a flue gas instrument. We also recommend one flue gas analysis per year to have a
better control over the combustion.
Accumulator tank
But it is not financially sustainably to install an accumulator tank in connection with the installation of the
burner if you e.g. will not have a solar installation or choose to mount the burner as a complement in a wood
boiler.
Electrical installation
All electrical connections on the burner and auger have high speed contact device see below.
1. To temperature sensor.
2. To feed auger ( 230 v )
3. Power lead in ( 230 v )
The protection cover of the burner can not be removed without pulling out all cables from the devices.
The cable for supply voltage to the burner shall be connected by authorized electrician via the overheating
protection of the boiler. Remaining connections have prepared cabling with connection devices that come with
the burner.
N.B.! THE BURNER SHALL ACCORDING TO LAW BE CONNECTED TO AN EXTERNAL OVERHEATING PROTECTION WITH
MANUAL RESET.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ulma 40 Kw at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ulma 40 Kw in the language / languages: English as an attachment in your email.

The manual is 1,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ulma 40 Kw

Ulma 40 Kw User Manual - Dutch - 10 pages

Ulma 40 Kw User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info