804591
8
Zoom out
Zoom in
Previous page
1/126
Next page
8
protected materials against corrosion.
9. Checking electrical devices
The repair and the maintenance of electrical components must include initial safety checks
and component inspection procedures. If there is a failure that could compromise the safety,
the circuit must not be connected to any power source until the failure is treated
satisfactorily. If the failure cannot be corrected immediately, but operating is still necessary,
an appropriate temporary solution should be used. This must be reported to the owner of
the equipment so that all parties are informed. The initial safety checks shall be carried out
if:
-capacitors are discharged: this is done in a safe manner to avoid the occurrence of
sparks;
-electrical components and electrical cables are not exposed during charging,
refurbishing or cleaning the plant;
-there is grounding continuity.
10.Repair of sealed items
While sealed items are being repaired, all power sources must be disconnected from the
equipment it must be intervened on, before any removal of the sealed caps, etc. If it is
absolutely necessary to power the equipment during service, then a continuous leakage
detection system should be considered at the most critical point to warn in case of a
potentially hazardous situation.
Particular attention must be paid to the following aspects in order to ensure that while
working on the electrical components, the housing is not modified in such a way that the
protection level is affected. These include cable damage, excessive number of connections,
terminals which do not comply with the original specifications, seals damage, improper
seals fitting, etc.
Ensure that the appliance is safely mounted. Ensure that the seals or the sealing materials
are not degraded so that they are no longer used for the purpose of preventing the
penetration of flammable gases. Spare parts must be in accordance with the specifications
of the manufacturer.
11.Repairs brought to intrinsically safe components
Do not use permanent inductive or capacitive loads in the circuit without ensuring that they
do not exceed the voltage and power allowed for the equipment used. The intrinsically
safe components are the only types it can be worked on in the presence of a flammable
atmosphere. The test appliance must be correctly evaluated. Replace the components only
with the parts specified by the manufacturer. Other components may cause the ignition of
the refrigerant in the atmosphere due to a leakage.
12. Cables
Check that the cables will not be subjected to wear, corrosion, excessive pressure, vibrations,
sharp edges or other adverse effects on the environment. Verification should also take into
account the effects of the deterioration over time or of the continuous vibrations from
sources such as compressors or fans.
13. Detection of flammable refrigerants
Potential sources of ignition should not be used under any circumstances when searching or
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Turbionaire Smart 10 eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Turbionaire Smart 10 eco in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 13.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info