between 30 and 60 seconds until a copious flush of water flows from
the side port of the valve.
џLower the valve lever.
WARNING! If no water is flowing from the valve port or it is too weak
(under normal water-supply pressure), this is a fault and indicates the
presence of impurities inflowing from the water main or resulting from
plumbing connections have blocked the safety vent of the combined
valve.
IT IS PROHIBITED to proceed to electrical connection of the appliance until
the reason for failure is not eliminated!
WARNING! Non-observance of the requirements for connection to the
water supply system may result in partial filling of the tank with water and
malfunction of the heating element. If the combination valve is not
installed or it has been improperly installed, this may even result in
destruction of the water tank, premises and/or other material and non-
material damage. Such sequences are not within the scope of the
warranty obligations of the manufacturer and retailer and will be borne by
the party who did not observe the requirements these instructions.
WARNING! The combined non-return-safety valve is one of the
protective fittings ensuring the safety of the water heater. It is strictly
PROHIBITED to use the water heater with a defective or removed/non-
installed combined valve!
Connection of the water heater to the water supply system must only be
performed by specialists.
The safety valve, if appropriate, will be used to drain water from the tank.
This shall be performed as follows:
џDisconnect the water heater from the mains from the additional device
and, for more security, turn off the safety fuse that is in the phase circuit
to the water heater.
џShut the cold water flow to the appliance by closing the tap (4 in Figure
3).
џOpen a hot water tap of a mixing cock or disconnect the coupling of the
hot water pipe (outlet pipe) of the unit.
џOpen the tap (10 in Figure 3) and wait until the water stops flowing from
the opening of the drain hose. The height between the tap and the end
of the hose should be at least 600mm.
These operations do not ensure that the water tank is completely drained.
Draining should only be performed by a qualified technician because it
involves disconnection of the electrical circuit of the appliance and removal
of the water heater flange.
WARNING! IT IS STRICTLY PROHIBITED to turn the water heater on
while its tank is partially or completely drained! Before you turn the
appliance on again make sure the tank is full of water.
WARNING! When draining water from the tank, it is necessary to take all
appropriate measures to prevent damage caused by leaking water.
WATER HEATER ELECTRICAL CONNECTION
WARNING! Before you switch the power supply, make sure the
appliance is full of water!
The water heater is an appliance with a degree of protection against electric
shock Class I, which requires its mandatory connection to the grounding
circuit of the electrical wiring.
The electrical power supply of the water heater is 230 V~ and is performed
by a separate electrical circuit via a three-core insulated cable with a cross-
2
section of each core of 2.5 mm (phase, neutral and protective). If the
protective conductor/core has attachment points, they should be safely
secured against self-loosening. Otherwise, the appliance will not be
properly protection connected that will impair its safety.
In the phase circuit it is obligatory to fit an electric fuse 16 А. The electric
wiring to which the water heater will be connected should be constructed in
line with the requirements of relevant standards. In the event that relevant
standards do not stipulate it, it is recommended that an automatic protection
against leak currents (residual current device) be installed in the electrical
circuit of the water heater.
Your water heater is fitted with a factory power supply cord combined with a
plug and it is electrically connected when the plug on the cord is plugged into
a working and grounded power socket of the premises’ electrical installation.
The socket must be protected against moisture, be spray-proof, connected
to a separate electrical circuit intended only for the water heater and
positioned in such a way as to be easily accessible after the appliance
installation. The water heater is switched off from the electrical installation
when the plug of the cord is pulled from the socket. Damaged and/or
improper electrical installation, and/or socket are major hazard, it may
cause accidents, product damages or impose risks to the environment,
objects and humans.
In the event that the purchased water heater has no factory fitted plug on the
power supply, connect its conductors to the electrical installation as follows:
џconductor with brown insulation to the phase conductor
џconductor with blue insulation to the neutral conductor
џconductor with yellow-green insulation to the safety conductor
WARNING! If the appliance power cord is connected to the electrical
installation in a wet room, the connection must be waterproof!
After appliance connection to the electrical installation it is necessary to
check its functionality.
WARNING! Non-observance of the electrical connection requirements
will impair the appliance safety, whereby its use is prohibited. Any
adverse consequences resulting from non-observance of the
requirements on appliance electrical connection are not within the scope
of the warranty obligations of the manufacturer and retailer and will be
borne by the party who failed to observe the requirements in these
instructions.
Only suitably qualified specialist must perform the connecting of the water
heater to the electric network and check its functionality. It is not obligation of
the manufacturer or retailer and is not covered by the guarantee.
HOW TO USE THE APPLIANCE
The water heater is controlled by an electronic control unit (thermoregulator,
controller) that controls directly two electric heating elements using two NTC
thermal sensors for measuring the relevant temperatures in each water
tank. The thermoregulator is controlled and set by self-explanatory and
intuitive menus by means of 4 multifunctional buttons. The specific function
of each button can be changed and its current status is displayed with
appropriate graphic on an information bar on the screen. There is an option
to rotate screen images 90 degrees if the unit is installed in a vertical
position, for easy reading.
The thermoregulator has 5 main operation modes:
џ‘Standby‘,
џ‘Heating’ to maintain the preset temperature,
џ‘Smart Control’ automatic heating temperature selection mode to
achieve maximum energy cost savings,
џA self-learning mode to measure and save the individual hot water
consumption schedule.
џ‚Timers’ mode enabling manual entry of heating time and temperature
by means of up to seven week timers.
The thermoregulator has a Delayed start function which allows a switched
off water heater to be switched on at a user-set time within 24 hours from the
current moment. In the event of failure of the power supply, the
thermoregulator will save its current operation mode, settings, time and
date.
The thermoregulator may be equipped with a WiFi module NRM-W3 for
connecting to the remote monitoring system and control through the
Internet.
Menus and screen in different languages, buttons and their functions,
technical specifications and error messages are specified and described at
the beginning of this booklet. In each figure, screens are shown in Arabic
numerals in brackets and buttons are shown in Roman numerals.
MAIN SCREEN - FIG. 5
When the power supply is switched on, the hardware and software version
of the electronic control unit is displayed for 2 seconds.
WARNING! Do not switch the appliance on if it is suspected of being
frozen! This will damage the water heater and the tank.
Then the main screen is displayed, which differs for the operation mode and
setting for vertical (1) or horizontal (2) installation. Each view of the main
screen has information that is essential for the relevant operation mode. In
the middle of each screen there is a color decorative line with different colors
depending on different operation modes.
EN EN
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TTulpe Smart Master DV060D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TTulpe Smart Master DV060D in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info