Always observe the operating instructions and “Impor-
tant operating notes” prior to starting! The vehicle owner
is responsible for the correct operation of the appliance.
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if necessary.
Before using for the first time, it is essential to flush the
entire water supply system through with clean water. If
the heater is not being used, always drain the water contents
if there is a risk of frost. There shall be no claims under
guarantee for damage caused by frost!
Materials in the device which come into contact with water
are suitable for use with drinking water (see manufacturer
declaration: www.truma.com – Manufacturer Declaration).
Power selector switch
Combi E
230
V~
e
d
f
g
b
c
a
a = Power selection rotary switch
b = Electric operation 230 V, 1800 W
c = Electric operation 230 V, 900 W
d = Gas operation
e = Mixed operation* (900 W gas and electrical operation)
f = Mixed operation* (1800 W gas and electrical operation)
g = Yellow LED on = “Electrical operation
* Winter mode only!
In summer mode the unit automatically selects electric opera-
tion at the preselected electrical power of 900 W or 1800 W.
Switching on the electric heating elements as well
does not increase the maximum heating power.
Control panel
1
3
5
7
9
40
°
60
°
60
°
Combi
1
2
3
4
5
l
m
o
k
h
p, r
n
h = Rotary switch for room temperature (1 – 5)
k = green LED lit “Operation”
green LED blinking
“after-running” is active in order to reduce the unit’s
temperature
l = Summer operation
(water temperature 40 °C or 60 °C)
m = Winter o peration
(heating without water temperature monitoring
or with drained water system)
n = Winter operation
(heating with water temperature monitoring)
o = Rotary “Off” switch
p = yellow LED lit “Boiler heat-up phase”
r = red LED lit, red LED blinking “Failure”
The LEDs are visible only when the unit is switched on.
Operating instructions
Controller connecting hoses that meet national regulations
must always be used in the respective country for which the
equipment is destined. These hoses must be checked regu-
larly for brittleness. Winter-proof special hoses must always
be used if the equipment is operated during the winter.
Pressure regulating equipment and hoses must be replaced
with new ones no more than 10 years after the date of
manufacture (every 8 years if used commercially). This is the
responsibility of the operator.
Important operating notes
If the cowl has been placed near or directly beneath an open-
ing window, the device must be equipped with an automatic
shut-off device in order to prevent operation with the window
open.
The integrity and tight fit of the exhaust gas double duct must
be checked regularly, particularly at the end of long trips. Also
check the mounting of the appliance and the cowl.
Following a blow-back (misfire) always have the exhaust gas
system checked by an expert!
Always keep the cowl for the exhaust duct and combustion air
intake free of contamination (slush, ice, leaves etc.).
The hot air outlets and the recirculated air intake openings
must be free so that the unit does not overheat. The integrat-
ed temperature limiter blocks the gas supply when the unit
becomes too hot.
Directive 2004/78/EC stipulates that a safety shut-off device is
required if motor homes are being heated while driving.
The Truma gas pressure control systems SecuMotion /
MonoControl CS satisfy these requirements.
If no safety shut-off device (e.g. for the gas pressure
control system Truma SecuMotion / MonoControl CS)
has been installed, the gas cylinder needs to be closed when
driving and appropriate signs must be displayed in the gas
cylinder protection box and close to the control panel
The safety shut-off device is also recommended for safety
reasons if caravans are being heated while driving.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trumatic Combi 4 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trumatic Combi 4 E in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info