Technical data
determined in accordance with EN 624 or Truma test conditions
Manufacturer:
Truma Gerätetechnik GmbH & Co. KG
P.O. Box 1252
85637 Putzbrunn (Munich)
Germany
Water contents: 10 litres or 14 litres
Water pressure: up to max. 2.8 bar
Type of gas: Liquid gas (propane/butane)
Operating pressure: 30 mbar
(or 28 mbar butane/37 mbar propane)
Rated thermal output: 1500 W
Gas consumption: 120 g/h
Heating up time from approx. 15°C to approx. 70°C
(10 litres)
Gas operation: approx. 34 min.
Electrical operation: approx. 45 min.
Gas and electrical operation: approx. 25 min.
Heating up time from approx. 15°C to approx. 70°C
(14 litres)
Gas operation: approx. 50 min.
Electrical operation: approx. 72 min.
Gas and electrical operation: approx. 38 min.
Power consumption 12 V
Ignition: 0.17 A
Heating up: 0.08 A
Standby: 0.04 A
Power consumption 230 V
Heating up: (3.7 A) 850 W
Weight (empty): approx.: 6.7 kg
Declaration of conformity:
The Truma-Ultrastore model has been tested and approved
through the DVGW and fulfils the EC gas appliance guidelines
(90/396/EEC) as well as the associated EC guidelines.
The CE product number is available for EU countries:
CE-0085AP0038
EEC Type Approval:
e1 022604
The right to effect technical modifications is reserved!
Dimensions:
2. The operating pressure for the gas supply is 30 mbar (or
28 mbar butane/37 mbar propane) and must correspond to the
operating pressure of the appliance (see data plate).
3. Liquid gas systems must accord with the technical and ad-
ministrative regulations of the particular country in which they
are being used (e.g. EN 1949 for vehicles). National regulations
must be respected.
The testing of the gas system must be repeated every two
years by a qualified specialist and, if appropriate, confirmed on
the inspection certificate.
The vehicle owner is always responsible for arranging
the inspection.
4. Liquid gas equipment must not be used when refuelling, in
multi-storey car parks, in garages or on ferries.
5. During the initial operation of a brand new appliance (or
after it has not been used for some time), a slight amount of
fumes and a slight smell may be noticed for a short while.
Remedial action here is to immediately run the heater and to
ensure adequate room ventilation.
6. If the burner makes an unusual noise or if the flame lifts off,
it is likely that the gas pressure regulator is faulty and it is
essential to have it checked.
7. Items sensitive to heat (e.g. spray cans) must not be stored
in the installation area, since excess temperatures may under
circumstances be incurred there.
8. Only pressure control equipment that complies with EN 12864
(in vehicles) with a fixed delivery pressure of 30 mbar must be
used for the gas system. The flow rate of the pressure control
device must correspond to at least the maximum consumption
of all devices installed by the system manufacturer.
For vehicles we recommend the Truma caravan regulator and
the Duomatic Plus gas pressure regulator kit for the two-cylin-
der system. Truma regulators have been specially developed
for the harsh stress conditions in caravans and vehicles. As
well as a safety valve that provides protection against over-
pressure, they also have a pressure gauge that can be used to
check the tightness of the gas system. The pressure control
equipment should be operated with a de-icing system (Eis-Ex)
at temperatures around 0°C and below.
Regulator connecting hoses that meet national regulations
must always be used in the respective country for which the
equipment is destined. These hoses must be checked regularly
for brittleness. Winter-proof special hoses must always be
used if the equipment is operated during the winter.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Ultrastore Rapid at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Ultrastore Rapid in the language / languages: English as an attachment in your email.

The manual is 0,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info