Installation and repair are only to be carried out by an
expert!
The Therme is designed for pressure-free operation. In
order to enable the pressure, which builds up during the
heating up procedure, to escape, there is to be no non-return
valve installed in the cold water supply between Therme and
submergible pump.
When connecting to a central water supply (city mains) or
when using stronger pumps, a pressure reduction valve must
always be installed to prevent that pressures above 1.2 bar
develop in the Therme. In addition, a safety/drain valve
(accessory, part no. 70141-10) must be installed into the cold
water supply line.
Only tap fittings with electrical switch are to be used!
Water supply
When installing a water supply into the vehicle, please ensure
that there is an adequate distance between the water hoses
and the heat source (e.g. heater, warm air duct).
A water hose may only be fitted at a clearance of 1.5 m to the
heater on the warm air duct. The Truma hose clip SC (part no.
40712-01) can be used if this distance is observed. In the case
of parallel installations, e.g. openings through a wall, a spacer
element should also be attached (e.g. insulation) to prevent
contact.
Choice of location
Select an installation location near the heater (not in the
installation space behind the heater).
If there are two bleeding points (fig. B), please select an in-
stallation location where the hot water pipes can be as short
as possible.
Installation of the Therme
Place the Therme on the floor on its mounting supports and
bolt down into place.
Insert hot air hoses at both sides. If no hot air supply is to be
connected, seal both air connection fittings using the VD seal-
ing cap (part no. 40353-01 – not included in scope of delivery).
Fitting the draining and venting valve
Draining and venting valves must be fitted in the immediate
proximity of the device (max. hose length 40 cm), at a point
which is the most readily accessible for the user.
To guarantee total emp tying of the water content,
both water lines must be laid so as to slope down to
the valves. There shall be no claims under guarantee for
damage caused by frost!
Drill two holes, diameter 11 mm, in the floor of the vehicle and
secure the valves (1 + 2) with 2 screws each.
Connect the connection nozzles (3 + 4) and the valves
(1 + 2) to the water hose, dia. 10 mm (max. length 40 cm).
Installation instructions
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Therme at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Therme in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 0,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Truma Therme

Truma Therme User Manual - English, German, Dutch, Danish, French, Italian, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info