10
tion is made directly to the
battery, the positive and ne-
gative leads are to be protec-
ted by fuses.
Secure all cables with clips!
If power pack units are used,
care must be taken to ensure
that the device can only be
operated with safety extra-
low voltage (SELV), in accor-
dance with EN 60742.
Note: As an accessory Truma
can supply a battery holder
(Art. No. 50000-27700) for
operation with a 9 V mono-
bloc battery.
Attention: Sustained
operation is not possible
with 9 V connection with
the Sonatic L!
In order to achieve maximum
operational duration, we re-
commend the use of an
alkali/manganese battery.
No display: - Check 12 V supply voltage
or replace 9 V battery
- Inside temperature in the
vehicle too low, min. 0°C
No sustained - 12 V voltage supply fallen - Charge the vehicle battery
operation possible: to below 10 V
Display flashing even - Dirt on cylinder base or on - Use only mild soapy water
with cylinder full: coupling pad on the cylin- for cleaning
der mount
- Cylinder has been placed
on the mount off-centre
- Foreign bodies in the gas - Turn the cylinder over once, or
cylinder knock on the cylinder surface
- Contact time for the gas - wait about 3 minutes
cylinder not maintained
- Cable interrupted or contact - Check the plug connections
plug loose
Filling level display too - Wrong measurement mode
low in 11 kg cylinder: - Contact time for the gas - wait about 3 minutes
cylinder not maintained
- Temperature matching at - wait about 15 minutes
the gas cylinder not
maintained
- Wrong gas cylinder size
Filling level display in 5 kg - Wrong measurement mode
cylinder too high: - Wrong gas cylinder size
Display - - -: - 9 V battery supply fallen - Replace the 9 V monobloc
below 7.5 V battery
- 12 V voltage supply - Charge the vehicle battery
fallen below 8 V
Trouble-shooting