726900
6
Zoom out
Zoom in
Previous page
1/62
Next page
ENB - 1 Operating manual dehumidifier TTK 120 S
The apparatus must never be covered or transported
during operation.
All electrical cables outside of the apparatus are to be
protected from damage (e.g. by animals).
Extension of the mains cables must be carried out with
due regard for the installed load of the apparatus, cable
length and application.
The apparatus may only be transported upright, the
condensate container must be emptied before each
change of location.
It is not permitted to operate or utilise the apparatus
in a manner other than that described in this manual.
All liabilities and warranty claims are invalidated in the
event of non-compliance with this stipulation.
Work on the refrigeration system and the electrical
equipment may only be carried out by an authorised
& qualified company!
Description of apparatus
The apparatus has been designed for automatic air
dehumidification. It can be easily transported and set
up due to its compact dimensions.
The apparatus works in accordance with the condensation
principle. It is equipped with a hermetically-sealed refrigeration
system, a low-noise, low-maintenance ventilator and a mains
cable with plug.
The apparatus has an operating console for function control.
The automatic control, the condensate container with inte -
grated overflow protection and the connection piece for direct
extraction of condensate permit fault-free continuous operation.
The apparatus conforms with the fundamental health & safety
requirements of the applicable EU legislation.
Application locations for the apparatus
The apparatus is used wherever dry rooms are required and
wherever subsequent economical damage (e.g. due to mould
formation) is to be avoided.
The apparatus is predominantly used to dry and
dehumidify:
Living, sleeping, shower or cellar rooms
Laundries, holiday homes, caravans and
motor homes, boats
And for the continuous drying of:
warehouses, archives, laboratories
Bathrooms, washing rooms & changing rooms.
Principle of operation
The unit works on the condensation principle. The ventilator
sucks the moist room air in through the air inlet, via the air filter,
the evaporator and the condenser that lies behind it. In the cold
evaporator heat is extracted from the room air. The room air is
cooled below the dew point, and the water vapour contained in
the air condenses as condensate or frost on the evaporator fins.
The ambient air is cooled to below the dew point and the water
vapour contained in the air condenses as condensate or frost
on the evaporator fins.
The dehumidified, cooled air is warmed again at the
condenser (heat exchanger) and is blown out at a tempera-
ture of approximately 5 °C above room temperature.
This treated, dryer air is then mixed with the ambient air.
Due to the continuous room air circulation through the
apparatus, the air humidity in the place of use is reduced
continually to the desired relative humidity.
Dependent on the air temperature and the relative air humidity,
the condensed water drops continually, or only during the
periodic defrosting phases, into the condensate pan and then
into the condensate container located below via the integrated
outlet.
A float valve, disposed in the condensate container, interrupts
the dehumidification operation via a microswitch when the
container is full.
A
A.1 A.2
A.3 A.4
OFF MAX.DRY
FULL
OFF MAX.DRY
B.4 B.5
C
B
B.2
FULL
B.1 B.6
B.9
B.8
B.7
B.3
Safety notes.............................................. B - 1
Description of apparatus ........................... B - 1
Set-up ...................................................... B - 2
Operation ................................................. B - 2
Commissioning......................................... B - 2
Shutting down........................................... B - 2
Filter cleaning ........................................... B - 3
Transportation of apparatus....................... B - 3
Care & maintenance ................................. B - 3
Troubleshooting ........................................ B - 3
Technical data .......................................... B - 3
Circuit diagram ......................................... B - 3
Spare parts list.......................................... B - 4
Spare parts overview ................................ B - 4
Care and maintenance log........................ B - 4
Overview of contents Safety notes
This manual should be read carefully before setting
up / using the apparatus, and it should always be kept
close to the place of use or on the machine!
The apparatus was subjected to extensive material, function and
quality tests before delivery.
Nevertheless, dangers can arise from the use of the apparatus
if it is incorrectly used by untrained personnel!
Please observe the following instructions.
The apparatus should not be set up and operated in
rooms where a danger of explosion exists.
The apparatus should not be set up and operated in
saliferous environments or where the ambient air
contains oil, sulphur or chlorine.
The apparatus must be placed upright in
a stable position.
The apparatus should not be subjected to direct
contact with running water.
Unrestricted access to the air intake and air exhaust
must always be guaranteed.
The air intake side must be kept free of dirt and
loose objects.
Never insert foreign objects into the apparatus.
A. Set-up
A.1 Keep windows closed
A.2 Keep doors closed
A.3 Keep apparatus at least 0.5 m away from walls
A.4 Keep apparatus away from heaters or other
sources of heat
B. Operation
B.1 Tank warning lamp
B.2 Rotary-type control switch
B.3 Hygrostat-controlled mode
B.4 Turn all the way left, machine off
B.5 Turn all the way right, permanent mode
B.6 Air intake
B.7 Condensate container (tank)
B.8 Connection port
B.9 Air filter with handle
C. Filter cleaning
Pictures of apparatus
This publication replaces all previous announcements. No part of this publication may be reproduced, processed using electronic systems, replicated or distributed in any
form, without our written authorisation. Subject to technical changes. All rights reserved. Names of goods are used without guarantee of free usage keeping to the
manufacturer's syntax. The names of goods used are registered and should be considered as such. We reserve the right to modify design in the interest of on-going
product improvement, such as shape and colour modifications. The scope of delivery may vary from that in the product description. All due care has been
taken in compiling this document. We accept no liability for errors or omissions. © TROTEC ®
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTK120S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTK120S in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 3,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info