727798
10
Zoom out
Zoom in
Previous page
1/13
Next page
10 EN
convector TCH 1500 E
The device goes off or does not start at all:
The device is not standing in an upright position, it is tilted.
The device is equipped with a sensor that switches the
device off if it is not standing in an upright position. Place
the device on its feet and make sure that it is standing in
an upright position.
The device does not run and the display shows "E1":
The room thermostat is not active. The device is provided
with an overheating protection that switches the devices
off when a temperature of 50 °C is exceeded. If the device
recognizes that no thermal sensor is active, it switches off
for reasons of safety.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
The device does not run and the display shows "E2":
Short circuit in the power circuit of the room thermostat.
Pull the mains plug and check the power connection.
Check the on-site fusing.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter Value
Model TCH 1500 E
Heating capacity
(depending on levels 1-10)
220–1500W
Heating capacity level 5 1000W
Setting range 5°C to 35°C
Mains connection 220 – 240V/ 50Hz
Max. power consumption 1500W
Cable length 1.5m
Dimensions
(depthx widthx height)
130x 1100x 230mm
Plug type CEE7/7
Minimum distance to walls
and other objects
A: top:
B: rear:
C: side:
D: front:
1m
1m
1m
1m
Weight 6.5kg
Remote control batteries Type LR03/ AAA– 1.5V (2pcs.)
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TCH1500E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TCH1500E in the language / languages: English as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TCH1500E

Trotec TCH1500E User Manual - German - 14 pages

Trotec TCH1500E User Manual - Dutch - 14 pages

Trotec TCH1500E User Manual - French - 15 pages

Trotec TCH1500E User Manual - Italian - 14 pages

Trotec TCH1500E User Manual - Polish - 14 pages

Trotec TCH1500E User Manual - Turkish - 14 pages

Trotec TCH1500E User Manual - Spanish - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info