laser distance measuring device BD 11
Operation
Switching the device on
Warning of laser radiation
Laser class2, Pmax.: <1mW, λ: 400-700nm,
EN60825-1:2014
Do not look directly into the laser beam or the opening
from which it emerges.
Never point the laser beam at people, animals or
reflective surfaces. Even brief eye contact can lead to
eye damage.
Examining the laser output aperture by use of optical
instruments (e.g. magnifying glass, magnifiers and the
like) entails the risk of eye damage.
When working with a laser of class2, observe the
national regulations on wearing eye protection.
1. Depending on the model version, briefly press the Switch-
on/ measurement button(7) once or twice.
ðThe display will be switched on and the device ready for
operation.
Switch-off
1. Press the Switch-off button(9) for a long time.
ðThe display is switched off.
Basic settings
Aborting the measurement and deleting the display
Briefly press the Delete button(9) to abort the current
measurement or to delete the displayed measured values one at
a time. The laser switches off for this purpose.
Setting the reference value
The device always measures the total distance starting at the
reference point. This means that if the rear end of the device is
set as reference point, the length of the device will be part of
the measurement. By default the reference point is set to the
rear of the device. You can, however, also relocate the
reference point to the front part of the device.
To do so, please proceed as follows:
1. Press the Reference button(8) for a long time to relocate
the reference point to the front end of the device.
ðThe Reference value front indication(12) appears on the
display.
2. Press the Reference button(8) for a long time once again
to relocate the reference point to the rear end of the
device.
When switching the device off and then on again, the reference
value will automatically be relocated to the rear end of the
device.
Changing the units
1. Press the Unit button(10) for a long time to switch
between the units for the measured values. Available units
are ft, in and m.
Calling up a measured value in the device history
The device automatically saves the last 10measured values.
The saved measured values can be called up as follows:
1. Briefly press the Function button(10) five times to call up
the history.
ðThe History indication(14) appears on the display.
2. Briefly press the Plus/ minus button(8) to navigate
through the history and call up the saved measured values.
ðIn the History indication(14) you can see which saved
measured value is currently displayed.
3. You can return to the normal measuring menu by briefly
pressing the Delete button(9).
4. By briefly pressing the Measurement button(7) you can
use the saved value for your current measurement.
Carrying out measurements
Warning of laser radiation
Laser class2, Pmax.: <1mW, λ: 400-700nm,
EN60825-1:2014
Do not look directly into the laser beam or the opening
from which it emerges.
Never point the laser beam at people, animals or
reflective surfaces. Even brief eye contact can lead to
eye damage.
Examining the laser output aperture by use of optical
instruments (e.g. magnifying glass, magnifiers and the
like) entails the risk of eye damage.
When working with a laser of class2, observe the
national regulations on wearing eye protection.
Info
Please note that moving from a cold area to a warm
area can lead to condensation forming on the device's
circuit board. This physical and unavoidable effect can
falsify the measurement. In this case, the display
shows either no measured values or they are incorrect.
Wait a few minutes until the device has become
adjusted to the changed conditions before carrying out
a measurement.
Info
For a correct measurement, please observe the
distances from the measuring object stated in the
technical data. If the reference point is less than
0.05metres away from the measuring object, the
device will not perform a measurement.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec BD11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec BD11 in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec BD11

Trotec BD11 User Manual - German - 12 pages

Trotec BD11 User Manual - Dutch - 12 pages

Trotec BD11 User Manual - French - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info