Operating Manual – Electronic Humidifier
EN
B - 3
3 SET button
With the Set button you can select from the sub-men-
us Taste (21, 22, 23 ) in programming mode. If no
other settings are made, after 10 seconds the display
automatically jumps back to the standard display fig-
ure, i.e. indoor atmospheric humidity. Changes that
have been made to the required humidity setting or
in programming mode are saved.
4 PROG button
Pressing this button opens the programming mode
of the B 500 so that you can select from the main
menus (10, 20, and 30). See page 9 for a descrip-
tion of the menus.
5 Flush button
Pressing this button activates the rinsing system.
(optional extra)
6 ON/OFF-Taste
The appliance can be switched on or off by pres-
sing this button.
m Supplied with two 24G Size AAA 1.5V batter-
ies.Please do not use any other type!
07. Filling
(not applicable for humidifiers with automatic
water supply)
The device is filled with water via the upper filler flap
using a watering can (only up to the max. level mark,
50 litres). The water level is indicated by light emitting
diodes (max. 5 stages). Both normal tap water and
softened water can be used to operate the humidifier.
m Do not use distilled water! Take care to fill
correctly, since spilt water could enter the
equipment and cause a short circuit. The
maximum temperature of the water must
not exceed 35 °C.
08. Water level indicator
The water level is sensed by copper electrodes and
is indicated by LEDs on the control panel. The device
switches off automatically if the red „Top up water“
LED comes on. A small quantity of water always re-
mains in the tank (approx. 15 litres). It is advisable
to regularly (approx. every 3-4 weeks) drain off the
residual water depending on the degree of soiling
and calcium (lime) content. The opportunity should be
taken to clean the water tank with a sponge or a wet
vacuum cleaner. The electrode rods require occasion-
al cleaning to ensure they do not indicate incorrect
values or cause the humidifier to shut down owing to
calcification of the voltage electrodes. Distilled water
must not be used because it leads to malfunctions in
the water level indicator.
Electrode rods
09. Filter change indicator
The B 500 atmospheric humidifier has a filter change
indicator. The frequency with which the filter needs to
be changed depends on the length of time for which
the pump runs, the hardness of the water, and the
fan. Under the best circumtstances it will have to be
changed after 98 days, in the worst after 56 days, but
this is only a recommendation; the situation can be
affected one way or the other by such external factors
as air pollution or the hardness of the water. In any
case it is advisable to make regular visual checks of
the filter Please see the section on „Changing the fil-
ter” for detailed instructions. When you have changed
the filter you have to reset the indicator manually to
its initial position. Please proceed as described in the
section on „Menu programming“ to Menu 33, where
you can reset the filter change indicator at any time to
its initial position of 98 days.
Filter change
Depending on the operating time of the humidifier,
the special filter is used up during the course of time
as a result of mineral deposits in the water and dust
deposits in the air (every 8-16 weeks depending on
the water hardness, dust accumulation and operating
time). The filter should not be washed as this reduces
the evaporation capacity of the device. All humidifi-
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec B500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec B500 in the language / languages: English, German, French as an attachment in your email.

The manual is 5,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info