8 EN
air washer AW 20 S
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check whether the upper and lower part are properly
connected to one another.
Wait for 10minutes before restarting the device.
If the device is not starting, have the electrics checked by
a specialist company or by Trotec.
Water is leaking:
Check whether the device is set up in a stable and upright
position.
Check the device for leaks.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Cleaning the water tank and replacing the (optional)
SecoSan® stick
Clean the water tank at least once a week and prior to every
start-up or shutdown.
ü The device is switched off and disconnected from the
mains.
ü The upper part of the device has already been removed
from the device.
1. Take the disk out of the water tank.
2. If required, take the SecoSan
®
stick out of the water tank.
3. Discharge the residual water into a drain.
4. Clean the inside of the water tank with a mild detergent.
5. Thoroughly rinse the water tank with clear water.
6. Dry the inside of the tank with a lint-free cloth.
7. If you want to continue using the SecoSan
®
stick, rinse it
thoroughly with clear water.
ð The SecoSan
®
stick should be exchanged approx. every
6months. The LED for the SecoSan
®
stick lights up
when an exchange is required. After replacement
dispose of the SecoSan
®
stick properly.
8. Insert the (new) SecoSan
®
stick in a corner of the water
tank. Make sure not to block the rotating disk.
9. Refit the disk. Check the disk for complete movability.
If necessary, reposition the SecoSan
®
stick so that the disk
can turn freely.
10. Fill the water tank with fresh drinking water.
11. Put the upper part back on the device.
If you replaced the SecoSan
®
stick, the SecoSan
®
stick
indication(15) needs to be reset after having switched the
device back on:
1. Simultaneously press and hold the buttons power(13) and
plasma generator(30) for approx. 3s.
ð The illuminated SecoSan
®
stick indication(15) goes out.
Cleaning the disk
ü The device is switched off and disconnected from the
mains.
ü The upper part of the device has already been removed
from the device.
1. In case of slight soiling, insert the Easy Kit between two of
the disks and move it back and forth.
2. In case of heavy soiling, you can disassemble the disk into
its individual components and clean them thoroughly:
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec AW20S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec AW20S in the language / languages: English as an attachment in your email.

The manual is 7,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec AW20S

Trotec AW20S User Manual - German - 12 pages

Trotec AW20S User Manual - Dutch - 14 pages

Trotec AW20S User Manual - French - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info