8. DATA CAPTURE FUNCITON
EO1-11138
8-1
9. DATA CAPTURE FUNCITON
8.DATA CAPTURE FUNCTION
(1) Function
To make it possible to transfer data to the PC, the details of registration jobs performed on each terminal
are pooled in the master terminal (M) as transaction data.
(2) Buffering Transaction Data
When a terminal performs the finalize operation,transaction data entered in registrations is sent to the
master terminal (M). The master terminal (M) receives the transaction data and pools it in the transaction
buffer.
The transaction data is controlled usually in two buffers. One is for buffering transaction data and the other
is for collecting data from the PC. (When one buffer becomes full, or when the collection request is issued
from the PC, the buffer in use is released for the PC, and the other buffer is used for subsequent
buffering.)
(3) Collecting Transaction Data
The transaction data stored in the master terminal is sent to the PC according to the request from the PC.
If the buffer becomes full when the master terminal receives the transaction data request command from
the PC, the transaction data of the full buffer is sent to the PC. If the buffer is not full,the transaction data in
the buffer (the buffer used for buffering) is sent to the PC.
(4) Processing when the Transaction Buffer is Full
When transaction data is received from the terminal (BM, S), the master terminal checks the vacant area of
the transaction buffer. If the received transaction data cannot be stored in the buffer, the master terminal
sends to the terminal a response indicating that the buffer is full. The terminal receiving this response,
performs journal printing indicating that the transaction data is missing.
(5) Supplementary
Only when the transaction data capture function is selected by program option, transaction data can be
sent/received and buffered.
There is no warning reporting the remaining capacity of the transaction buffer.
Once the transaction data collection command is issued,data in one buffer is collected.
(When data in two buffers is required,this command should be issued twice.)
203


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba TEC FS-2600-1 SERIES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba TEC FS-2600-1 SERIES in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info