693097
6
Zoom out
Zoom in
Previous page
1/8
Next page
d. Press to conrm the settings.
e. "SAVED" will display and back to previous screen.
adjusting the ticking sound:
The audible ticking sound gives reassurance that your sensor pad is correctly connected and the monitor is
sensing movement. If you wish to switch o the ticking sound:
Press and +/- to go to TICK TONE menu in parent unit.
Press and +/- to go to SENSITIVITY menu in parent unit.
Press and the current status is displayed.
Press +/- to select ON or OFF.
Press to conrm the settings.
"SAVED" will display and back to previous screen.
adjusting the sensitivity of the sensor pad:
This monitor is compatible with standard cot mattresses. With thicker mattresses (ie spring interior) you
may need to adjust the sensitivity switch on the baby unit (14) from it’s preset ‘medium position to the
high’ position. With some very thin mattresses you may need to change the sensitivity setting to low’.
WARNINGS ABOUT USING THE SENSOR PAD!
A moving or swinging cord may be interpreted by the sensor pad as a baby’s movement. To avoid this,
ensure that the cord is not positioned where it may be subject to movement.
You should ensure there is no vibration in or near the nursery, so that the sensor pad is monitoring
only your baby’s movements.
The sensor pad does not carry any electricity and will not aect your baby even if the mattress is
subject to bedwetting or vomiting.
Never immerse the sensor pad in liquid. To clean, wipe with a dry, lint free cloth.
Never place the connecting cord in contact with any moving objects, or near any heated surface.
Always ensure wires and cables are out of reach from your baby and younger children and never place
connecting cords amongst your baby’s bedding, the child could be strangled.
Ensure the sensor pad is used the correct way up.
Do not immerse sensor pad in liquid and avoid contact with moisture.
testing the movement sensor pad function on the parent unit:
To test the sensor pad function on the parent unit you will need someone else to carry out the sensor
pad functions on the baby unit.
If the sensor pad switch has been turned on at the baby unit the 5th LED (E) on the parent unit will light
up GREEN, and you will hear the tick sound.
When no movement has been detected for appro x. 20 seconds the 5th LED (E) on the parent unit will
light up RED and you will hear the sensor pad alarm.
If movement is detected again after the alarm has activated then the red alarm light will change to
ashing mode.
To reset the alarm it will be necessary to go to the baby unit and turn it o then on again.
if the movement sensor alarm sounds:
The Tommee Tippee Closer to Nature sensor pad monitor is NOT a medical device and is NOT designed
to prevent cases of sudden infant death syndrome (SIDS). This Tommee Tippee Closer to Nature
monitor is intended to help you monitor your child and is NOT to be used as a substitute for adult
supervision.
The alarm going o may not be a sign of a problem with your baby. It may be a sign that the baby has
moved away from the sensor pad area, or that batteries are running low if not mains power operated.
adjusting the sound sensitivity settings of the baby unit:
The sound sensitivity settings of the baby unit can be changed only when parent unit is linked with
the baby unit.
TO CHANGE THE SENSITIVITY SETTINGS:
a. Press and +/- to go to SENSITIVITY menu in parent unit.
b. Press and the current sensitivity level is displayed.
c. Press +/- to adjust the sensitivity level from Level 1 to Level 5
KEYS LCD DISPLAY
level
level
level
level
level
EXPLANATION
level 5
level 4
level 3
level 2
level 1

8 If the parent unit is linked with the baby unit successfully, the sensor pad icon will indicate on the
parent unit. The 5th LED (E) will light up Green if movement is detected.
9 If the sensor pad switch is on without the sensor pad connected securely, there is an error tone from
the baby unit and the sensor pad icon with image of in the parent unit will ash. A Text Prompt
on the parent unit 'Connect Pad' will also ash.
10 If the sensor pad is securely installed, after 20 seconds without detecting any movement, the alarm will
be triggered on both parent unit and the baby unit and the red alarm light will come on. The LCD will
show 'CHECK BABY' until the sensor pad is reset.
11 If movement is detected again after the alarm has activated then the alarm will stop and the red alarm
light will ash in both the parent unit and the baby unit to let you know that a problem has occurred and
the baby should be checked. The LCD will show 'CHECK BABY' until the sensor pad is reset.
12 To reset the alarm, switch the sensor pad o and on again.
1
2
3
4
5
6
PROBLEM SOLVING IF YOUR SENSOR PAD TEST FAILS:
No alarm after 20 seconds
if NO movement
False alarm when there IS
movement
Make sure there is no movement or vibration around the
sensor pad and test again. If alarm triggers again, decrease
sensitivity setting and test again.
Check the connections are secure and test again. If alarm
triggers again, increase sensitivity setting and test again.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tommee Tippee 1082S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tommee Tippee 1082S in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info