600939
18
Zoom out
Zoom in
Previous page
1/37
Next page
18
Signal indication of the mass remote control (MRC)
The presence of the MRC signal is indicated by the HDO (MRC) pilot light. If it is turned on, it means that
the full boiler input is allowed.
Reduction of the boiler input by way of MRC signal can be set in the service menu by means of the Ph¯ (P4.4) item.
Displaying the error messages
If you press (or double press) the (SELECT) button (5), the error message dialogue opens. This display
dialogue is indicated by the letter E in the first position of the digital display. If an error message is generated, it
is displayed automatically. To display any other variable, press buttons 1, 2 and 5.
If several simultaneous error messages occur, all of them are displayed (each for one roughly second): e.g.
E.02 – E.04 – E.05 – E.02 – E.04 – E.05 – ...
E.00 no defect
E.01 is a defect of one of the power relay contacts.
Boiler operation is not possible in any mode.
E.02 is low TOP water pressure in the heating system.
Boiler operation is not possible in any mode.
Water pressure measured by analogous pressure sensor is below 0.5 bar.
E.03 is a disconnection of the blocking element 2.
Boiler operation is not possible in any mode.
E.04 is a defect on NTC sensor for the TOP heating water temperature.
Boiler operation is not possible in any mode.
When the respective value is displayed, the lower dashes ( _ _ _ ) are displayed in the case of disconnection or
interruption of the sensor or its wiring, the upper dashes ( ¯ ¯ ¯ ) if there is a short circuit on the sensor or its
wiring.
E.05 is a defect of NTC sensor for DHW temperature. The boiler operation in the heating mode is possible,
DHW heating is not possible in the b_c (storage tank with sensor) mode and it is possible in the b_n (storage
tank with thermostat) mode. For further details see the rtU parameter for the operation of the DHW heating in
the service menu.
If the respective temperature setting is selected, lower dashes (_ _ _) are displayed if the sensor or wiring have
been disconnected or interrupted, upper dashes ( ¯ ¯ ¯ ) are displayed for short circuit on the sensor or wiring.
E.06 defect emergency thermostat of TOP heating water temperature.
Boiler operation is not possible (only after
a manual reset!).
E.07 is a defect of the NTC sensor for outdoor/room temperature. Boiler operation in the heating mode is
possible. If, however, the EtE heating mode (equitherm regulation) or Prt (integrated room thermostat) are
selected, the boiler automatically switches to the boiler thermostat mode (outlet water temperature control
according to a value set by buttons 1). DHW heating is possible in any of the modes.
If a respective display is selected, the lower dashes ( _ _ _ ) are displayed if the sensor or wiring have become
disconnected or interrupted, upper dashes ( ¯ ¯ ¯ ) stand for short circuit on the sensor or wiring.
E.08 reserve
E.09 is a defect of the TOP heating water pressure sensoranalogous sensor.
Boiler operation is not possible in any
of the modes.
E.10 is a defect of the communication between boilers connected in a cascade which has been detected by the
master boiler. To display the details about this defect, press button 5. Addresses of all boilers are alternately
displayed (each for the time of approximately 1 second) which do not communicate with the master boiler:
E.10 – c.04 – c.05 – E.10 – c.04 – c.05 – ...
E.11 is a defect of communication between boilers connected in a cascade which has been detected by one of
the slave boilers.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermona THERM EL 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermona THERM EL 30 in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info