600937
19
Zoom out
Zoom in
Previous page
1/37
Next page
19
Displaying the instantaneous boiler output
If you press (or double press) the (SELECT) button (5), the display dialogue of the instantaneous boiler
output opens. This dialogue is indicated by the letter P in the first position of the display. The output is shown in
kW (P.2.5 =2.5 kW, P.18 = 18 kW etc.).
8. User menu
Accessing the user menu
To access the user menu, press the
O/I (MENU)
button (3) for more than 2 seconds. To move between the
menu items, press the , buttons (1). If you want to change the input values, press the , buttons (2).
The entered value in the menu must be confirmed by pressing the
O/I (ENTER)
button (4). Exit the menu and
data input by pressing the
O/I (MENU)
button (3).
The menu item (the set variable) and its value display alternately (e.g. Et1 1.6 Et1 1.6...). The menu
item is displayed either by means of mnemotechnical texts (Et1) or numerical parameters (P1.1). The display
mode is set in the menu by way of the diS (P3.2) item.
User menu items
Group 1: Integrated equitherm regulation parameters
Equitherm regulation defines the desired value of heating water temperature depending on the outdoor
temperature. The selection of parameters for the calculation depends on the specification of the binary NU
(night moderation).
If NU is disconnected, the following is true:
the desired heating water temperature value = (20 – outdoor temperature) * Et1 + 20 + ET2
If NU is connected, the following is true:
the desired value of heating water temperature = (20 – outdoor temperature) * Et3 + 20 + ET4
The desired outlet heating water temperature value is limited in the range between to_ (P3.3) and to¯ (P3.4).
Equitherm regulation always requires the connection of an outdoor temperature sensor and the heating mode
setting of rto = EtE (P3.1=2).
Et1 P1.1 Equitherm regulation parameter, curve slope. True for a disconnected NU.
The setting range falls between 0.1 .. 6.0, step of 0.1, leading value is 1.6.
Et2 P1.2 Equitherm regulation parameter, curve shift. True for a disconnected NU.
The setting range is -20°C .. +40°C, step of 1°C, leading value is 0.
Et3 P1.3 Equitherm regulation parameter, curve slope. True for a disconnected NU.
The setting range falls between 0.1 .. 6.0, step of 0.1, leading value is 1.6.
Et4 P1.4 Equitherm regulation parameter, curve shift. True for a connected NU.
The setting range falls between -20°C .. +40°C, step of 1°C, leading value is -5.
19


Need help? Post your question in this forum.

Forumrules
1

Forum

thermona-therm-el-15

Reset search

  • I Have an EL15 and cannot see how to connect a 3 way motorised valve. Manual shows position on diagram but how is connection physically made? Please help Submitted on 28-9-2022 at 18:47

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermona THERM EL 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermona THERM EL 15 in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info