Mounting using the roof vent flange option
The flue terminal can be located at any random place on the roof face (supply and exhaust in identical pressure
areas) and must meet the applicable rules and regulations.
* A roofing sheet for a flat roof or a roofing sheet lead for sloping tiled roofs can be used for a watertight duct.
Use various bends, if required, for the slope. The recess in the roof decking should be 5 cm larger all around in
connection with having sufficient fire resistance. Centring plates can be used against the roof decking.
NEN 6068 (resistance definition in relation to the spread of fire between rooms) must be taken into consideration
in connection with the provisions made by the (local) Building Regulations. A casing made of fireproof material
(e.g. 12 mm Promatect fire resistant plate) must be used at 25mm from the outside flue.
Determine the position of the apparatus and the outlet and begin the construction of the flue with the connection
on the apparatus (always 1 metre vertical first) pay attention to the direction of installation. The inner flue must
be installed for draining. Connect the elements by using clamping straps. Ensure that the gastightness of all con-
nections is correct. A fitted pipe can be used in between the bends or when making the connection to the unit
and/or the roof vent flange. Use 2 wall brackets to support the flue on each floor.
CC FLUE SYSTEM PIECE CODE NUMBERS
DESCRIPTION MEASURE ( mm ) CODE NR. STAINLES
STEEL
A) CONCENTRIC PIPE 1000
500
250
401410100000
401410050000
401100250004
B) CONCENTRIC BEND 45° SET
401420045002
C) WALL BRACKET
401430110000
D) NOT AVAILABLE
E) CONCENTRIC BEND 90°
401420090000
F) WALL BAND ADJUSTABLE
401430120000
G) ADJUSTABLE LENGHT 250
4014 12025000
H) FLAT ROOF PLATE
401450150000
I) LOCKING BAND
401430100000
J) ADJUSTABLE ROOF PLATES (SET)
4014 50130000
K) FLAT ROOF FLASHING ALUMINIUM
401472000000*
L) STORM COLLAR / ROSETTE
401470100000
M) HORIZONTAL TERMINAL EXC.
401450160000
N) SLOPE ROOF FLASHING 20-45° LEAD
401476020000
O) VERTICAL TERMINAL
401450180000
P) SLOOP ROOF FLASHING 5-30°
401474005000
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Coventry S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Coventry S in the language / languages: English as an attachment in your email.

The manual is 3,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info