to test the operating functionality of the valve. Handle (Fig. 1, p. 15) is intended to open
the valve. It is necessary to control when operating water heater this handle to be in
position closing water draining from the tank.
5. SPECIFYING SECURITY MEASURES
Electrical safety and corrosion protection of EWH are guaranteed only if there is an
effective grounding in accordance with applicable electric installation rules and regula-
tions.
Plumbing pipes and fittings shall conform to parameters of water main and have
the required certificates of quality.
When installing and operating EWH the following is not allowed:
To power EWH if EWH is not filled with water.
To remove the protective cover when the power is on.
Use EWH without grounding or use water pipes as grounding.
To connect EWH to water supply with pressure exceeding 0.7 MPa.
To connect EWH to the water supply without safety valve.
To drain water from EWH with power switched on.
To use spare parts not recommended by the manufacturer.
To use water from the EWH for cooking.
To use water containing impurities (sand, small stones), which might lead to
EWH and safety valve breakdown.
To modify design and installation dimensions of EWH brackets.
Ambient temperature shall be within the range of С to 40ºС. Water in freezing
EWH at negative temperatures results in malfunction, which is not a warranty case.
Attention should be paid to children so that they do not play with EWH.
EWH is not intended for use by persons (including children) with limited
physical, sensory or mental capabilities, or by persons who do not know
how to use the EWH, except for cases when this happens under the
supervision or instructions by persons responsible for safety of the EWH.
During EWH operation, it shall be inspected regularly for proper health (absence
of dripping, burning smell, wiring sparks, etc.). In the case of long interruptions in water
heater operation, water supply failures, EWH shall be disabled and cold water inlet
valve shall be shut off.
ы
EN
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermex ID - shadow at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermex ID - shadow in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info