2.4 electrical installation
Connect the power cord
Before installation, the user shall establish a power supply device, which shall be equipped with the
main power switch of heating, protection equipment and other modifications to the home wiring,
including initial modification and application for electricity charges.
The casing used for wire connection, voltage regulator input and HDO, and possible cascade
interconnection (with small package parts attached) is located in the lower left corner of the bracket
(see above). In addition, external protection terminals should be installed (brass bolt M6).
Before installing the protection bolt, the sides and outside of the cabinet must be cleaned, and all the
places near the bolt will be unrestricted to the metal surface. Under the head of the inside of the
cabinet, use the end of the cable terminal to connect the protection wire. A brass nut with a lock
washer is tightened from the outside. Use another nut to connect to the second protection line.
After connecting the power cord, it is necessary to check whether the nuts of all power terminals and
contactor are properly tightened.
Simple and complex control elements, such as programmable (daily or weekly program) and indoor
regulators, can be purchased at the manufacturer and its contractual partners of the electric heating
boiler. In order for the electric heating boiler to work correctly, it is absolutely necessary to have the
regulator of the belt voltage output, which means that no external voltage should be supplied. The
required regulator output contact load capacity 230/0.1. An indoor regulator with no voltage output is
connected to PR1 and PR2 terminals.
indoor thermostat and remote control.
Note: indoor thermostat contacts must be clean. The output voltage 220V May damage the electronic
circuit. When installing day or week program indoor thermostat or time switch, should avoid to use the
device switch contact to switch on the power, they should be according to the device type by power
supply or batteries to power.
The designer must consider comprehensively the suitability assessment for the combination of
external equipment to remove power level boilers. Consideration must be given to boiler
functions related to households or houses and external equipment mentioned. The
manufacturer shall not be liable for any improper installation of the design.
1.Three - way connecting terminal
2.Water tank NTC connecting terminal
3.Indoor temperature controller connecting terminal
4.outdoor temperature controller connecting terminal
figure 7
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermex Eurostar at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermex Eurostar in the language / languages: English as an attachment in your email.

The manual is 1.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info