76
8.1 Programming weekly program with priority P1 .. P9
Example Channel C switches on daily at 8.15
Priority sequence P1.
Note: Pulse switching times can
also be fixed with priority
sequence.
For weekly programs with
priority, any number of
ON/OFF switching com-
mands can be specified.
Select Prog
Switch ON
Daily
Hours
Minutes
Priority P1
Store
The time period of a weekly program P1 .. P9 is fixed by entering a commence-
ment and finishing date. The weekly program begins at 0.
00
on the commence-
ment date and ends at 24
00
on the finishing date.
Example: As opposed to the normally active program on Channel C1 from
8 April until 27 May, the individual priority program with index P1 is to beco-
me effective. In the fixed time period with priority sequence P1 .. P9, the whole
standard program (without priority sequence) is suppressed.
8.2 Setting Time Period for Weekly Program P1 .. P9
Additional programming as described or with button v back into the auto-
matic program.
7)
Select P
Date Start
Confirm
Confirm
Date end
Store
A. Recurring annually