577039
5
Zoom out
Zoom in
Previous page
1/14
Next page
9
ScanTemp 410 – Infrared Thermometer
8
environment, take them to your retail store or to appro-
priate collection sites according to national or local
regulations.
Reminders:
Not recommended for use in measuring shiny or pol-
ished metal surfaces (stainless steel, aluminum, etc.)
The unit cannot measure through transparent surfaces
such as glass or plastic. It will measure the surface tem-
perature of the glass instead.
Steam, dust, smoke, etc., can prevent accurate measure-
ment by obstructing the unit’s optics.
Care and Cleaning:
The Sensor Lens is the most delicate part of the ther-
mometer. Please protect the sensor part from dirt. Gen-
tly clean it with a soft cloth moistened with water or
medical alcohol.
Avoid splashes and spills on the unit.
Store at a temperature of between -20°C to +65°C.
Specifications:
Temperature range: -60 .. +500 °C
(-76 .. +932 °F)
Accuracy: from -33…+500°C:
±2,0 °C or 2%,
whichever is greater
from 15…35°C: ±1°C
Operating environment: 0 .. +50 °C (32 .. 122°F)
Storing conditions: -20 .. +65 °C (-4 .. 149°F)
Response time: 1 second
Optical resolution: 12:1
Emissivity: 0.95 fixed
Battery life: Minimum 14 hours
Dimension: 175 x 39 x 80 mm
Weight: 180 g
ScanTemp 410 – Infrared Thermometer
°C
°C
Error messages
Temperature taken is not within the
measuring range:
“Hi“ = Temperature is higher than
500°C (932°F)
“Lo“ = Temperature is lower than
-60°C (-76°F)
“Er2“= Rapid ambient temperature change
“Er3“= Ambient temperature not within the
operating range. Please pay attention
to the operation temperature of
about 0°C to 50°C. Wait at least
30 minutes to adapt the thermometer
to working temperature.
“Er“ = All other error messages:
Switch of the instrument, remove the
battery for 1 minute, then repower
it. If the error message does not dis-
appear, contact the retailer for
further service.
TFA Anl. No. 31.1115_03/10 15.03.2010 10:32 Uhr Seite 5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA 31.1115 ScanTemp 410 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA 31.1115 ScanTemp 410 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info