ScanTemp 410 – Infrared Thermometer
╞
Introduction:
We are confident you will find many uses for your
“ScanTemp 410” non contact thermometer. It is compact
and easy to use. Within one second you can safely measure
surface temperatures without contact, even of hot, haz-
ardous, or hard-to-reach objects.
With the laser pointer the measuring point can be focused
exactly.
Features:
• 2 x 1.5 Volt batteries AAA included
• Large LCD-display with backlight
• Indication of measured value and maximum value
• Auto power off after 15 seconds
• Switch °C/°F
• With laser pointer
Use:
• Just aim at the measuring
object and press the measure
button
• Read the surface tempera-
ture in a second.
Distance, Spot Size, and Field of View
As the distance (D) from the object increases, the spot size
(S) of the area measured by the unit becomes larger at a
ratio of D:S = 12:1. To get the most accurate temperature
reading, aim at the target as near as possible.
ScanTemp 410 – Infrared Thermometer
╞
Safety Cautions:
ƽ EMC/RFI
• Protect the unit from EMI (Electro
Magnetic Interference) from in-
duction heaters and microwave
ovens and Electro Static Discharge.
Readings may be affected if the
unit is operated within a radio fre-
quency electromagnetic field
strength of approximately 3 volts per meter, but the per-
formance of the instrument will not be permanently
affected.
ƽ Attention
• Do not look directly into the laser beam – permanent
eye damage may result.
• Keep out of the reach of children
• Protect the unit from “thermal shock” (caused by large
or abrupt ambient temperature changes).
• Do not leave the unit on or near objects of high temper-
ature.
• Not recommended for taking human temperature.
Battery:
• Change the battery when the middle or right battery
power symbol appears on the display (2 x 1,5 Volt AAA).
• Remove the battery compartment opening the cover in
direction of the arrow.
Attention: Confirm the unit is power off before chang-
ing battery.
• Attention: Please do not dispose of old electronic devices
and empty batteries in household waste. To protect the
°C/°F-Button Measure-Button
Battery OK Battery almost
exhausted
replace
soon
Battery
exhausted
replace
at once
TFA Anl. No. 31.1115_03/10 15.03.2010 10:32 Uhr Seite 4