Data Logger PC Software
www.ti.com
3.5.1 SimpliciTI Data Logger
The SimpliciTI Sync tab offers the possibility setting time/date of the watch including calibration data
besides reading out logged data.
Pairing watch and PC:
1. Activate the pairing on the PC by clicking on "Start Access Point". The eZ430-Chronos Data Logger
status line displays "Access point started. Now start watch in acc, ppt or sync mode" when the PC is
ready
2. Select "SYnC" on the eZ430-Chronos watch by pushing the "#" button (see detailed description in
Section 3.3.3).
3. Initiate pairing on the watch by pushing the "DOWN" button to activate the selected mode. After a short
time, the link is established
Setting the watch:
1. Select metric or imperial units.
2. Enter calibration data for the temperature and altitude OR read back the data from the watch by
clicking on "Read Watch"
3. Specify, which data should be logged
4. Define logging time interval (1 to 255 seconds), in which data is stored
5. Click "Copy System Time" to set watch according to read the PC's system time
6. Click "Set Watch" to transfer data to watch
7. The watch shows "DONE"
8. Push the "DOWN" button on watch to end connection
Reading out logged data:
1. Pair watch with PC in case not linked yet - see Pairing watch and PC above
2. Specify file name and location of log file
3. Click on "Download" to start data transfer
4. Push the "DOWN" button to stop connection when the transfer has finished.
The log file is stored in CSV format. Its content appears as one line per log. Each line starts with date,
time, heart rate, temperature, and altitude. Parameters which were not logged are set to zero (according
to settings in eZ430-Chronos Data Logger PC software).
42
eZ430-Chronos Software SLAU292DNovember 2009Revised March 2011
Submit Documentation Feedback
© 2009–2011, Texas Instruments Incorporated
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Texas Instruments eZ430-Chronos at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Texas Instruments eZ430-Chronos in the language / languages: English as an attachment in your email.

The manual is 7,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info