Port Statistics
To display STP port statistic info, click Device Management -> STP -> Port Statistics.
Application Example of MST
Typical application structure overview
As the topology shown above, Device 1 and Device 2 belong to the same domain (the same domain
name, the same modification level and the same instance mapping). Set VLAN 10, 30, 100 to map
instance 1 and set Device 1 as the root bridge of instance 1; Set VLAN 20, 40, 200 to map instance 2 and
set Device 2 as the root bridge of instance 2. In this way, it is possible to make better use of the alternate
paths available by using MSTP for different VLANs or groups of VLANs and realize the load balance.
Data Schema
Config Item
Data
Description
VLAN
Config switches
according to
allowed VLANs
Implemented by configuring
VLAN and port VLAN
80


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tenda TEG3224P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tenda TEG3224P in the language / languages: English as an attachment in your email.

The manual is 8,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info