Device Management
- 69 -
Priority
Set the priority of the switch.
Priority is an important reference to determine whether the switch will be
selected to work as root bridge, and switch with higher priority will be
selected to work as root bridge under equivalent conditions. The lower
the value, the higher the priority. Priority is 32768 by default.
Hello Time
Set the time interval to 2 seconds by default for the switch to send
BPDU.
Max Age
Set the maximum survival time of BPDU message when it is stored on
the switch The default is 20 seconds.
Maximum aging time must meet the following requirements:
Maximum aging time ≥ 2 * (Hello Time + 1)
Maximum aging time ≤ 2 * (forwarding delay time – 1)
Forward Delay
Set the delay time of port status transition of the switch when a change in
network topology takes place. The default is 15 seconds.
Loopback Detection
Note
When the spanning tree functions are disabled, the loopback detection function, auto
awakening and awakening time interval cannot be set.
When the spanning tree function is enabled and the loopback detection function is
disabled, the auto wake-up function gets invalid. Auto wake-up function can get valid
only when both the STP function and loopback detection function are enabled.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tenda TEF1226P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tenda TEF1226P in the language / languages: English as an attachment in your email.

The manual is 3,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info