688848
16
Zoom out
Zoom in
Previous page
1/44
Next page
Energy 2510 D
Vers. 002
16
GB
Wait a couple of minutes before turning the
generating set off.
In certain situations, the data contained in the
microprocessor inside the panel may be altered.
This may be because the battery is very low, or
because the cables used to connect the battery
to the set have too small cross-sections. Altered
processor data may prevent the generating set
from running; to restore the functionality of
generating set, must reset the control panel.
7.3.2 Automatic Version (optional)
If you wish the start-up batteries to be recharged
automatically in the En 2510D generating sets, it
is possible to install the ASP (optional) automatic
control panel (fig. 25) instead of the manual
control panel.
The elements making it up are:
1 ON/OFF switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicator
5 Start-up failed indicator
6 Generator running indicator (flashing)
7 Maintenance request indicator
8 Fuel reserve indicator
9 Hour or voltmetric changeover switch button
10 Reset
11 Battery charged indicator
12 Automatic function indicator
13 AUTO/MAN switch for the automatic or
manual function
7.4 MANUAL operation
See section 7.1
7.4.1 AUTOMATIC operation
Turn the AUTO/MAN switch (fig. 25 ref. 13) to the
AUTO position and set the start-up switch (fig. 25
ref. 1) to ON position.
The automatic function indicator (fig. 25 ref. 12)
will light up. If the battery which supplies the
generating set has a voltage of more than 11.5
Volts, the battery charged indicator (fig. 25 ref.
11) will light up.
When the voltage at the ends of the 12V DC
terminals of the generating set is lower than 11.5
Volts, the battery charged light indicator (fig. 25
ref. 11) will go off and the generating set will
begin the start-up procedure (similar to that of the
manual operation).
During the operation in automatic mode, the
display (fig. 25 rif. 2) will show the total running
hours of the generating set. Press the hour or
voltmetric changeover switch button (fig. 25 ref.
9) to display the voltage at the ends of the 12V
DC terminals, i.e. at the ends of the battery.
When the battery is charged, and anyway after at
least 15 minutes’ running, the battery charged
hours indicator (fig. 25 ref. 11) will light up and
the electronic control panel will turn off the
generating set.
To select automatic or
manual mode is necessary to position the
AUTO / MAN switch before turning on the
panel with the ON / OFF switch..
Remember that the time which is taken by the
generating set in automatic mode to recharge the
battery may vary according to the battery status,
the amount of connected batteries and the ambi-
ent temperature.
Generally, the lower the temperature the less the
time required to charge the battery.
Applying any load higher
than the energy just then available in the
battery will prevent the generating set from
turning on due to insufficient voltage.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 2510D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 2510D in the language / languages: English as an attachment in your email.

The manual is 3,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info