688849
23
Zoom out
Zoom in
Previous page
1/40
Next page
Vers. 002
Energy 2510 B
GB
23
7.4.2 Air filter maintenance
A clogged air filter will re-
duce air flow to the carburettor. To prevent
carburettor malfunction, check the air filter
regularly. If the engine is used in a heavily
dusty environment, we suggest checking the
air filter every time before starting up the en-
gine.
Never use Diesel oil or
solvents with a low evaporation point for
cleaning the air filter cartridge, as this could
cause fires or explosions.
Never operate the engine without an air filter; the
engine would wear down quickly due to air-borne
dust.
To access the filter cartridge, remove the air filter
closing lid (Fig.36 Ref.3) after having unscrewed
both screws that fix it to the air filter box.
Take out the cartridge (Fig.36 Ref.1) and wash it
in mild detergent and water then rinse thor-
oughly. Let the filter cartridge dry out completely,
then dip it in clean engine oil. Squeeze out care-
fully any excess oil.
Replace the cartridge only if visibly worn out.
7.4.3 Spark plug maintenance
Use spark plug models BP4ES, BPR4ES (NGK),
W20EP-U, W20EPR-U (ND) or else spark plugs
made by other manufacturers but compatible with
the above.
Never use spark plugs with a different tempera-
ture degree from those listed above.
Take the cap off the spark plug
(Fig.36 Ref.2)
and using the special wrench take out the
plug.
Perform a visual inspection. Replace in case
of obvious wear or if the insulator is broken or
cracked.
Use a steel brush to clean the spark plug, if it
can be used again.
Use a thickness gauge to measure the dis-
tance between the electrodes. The right dis-
tance should be between 0.7 and 0.8 mm
(Fig. 37).
Correct the distance if necessary, bending the
side electrode.
Make sure that the spark plug washer is in
good condition and then screw back on by
hand to make sure that it is correctly put back
in place. Finally, tighten to the right torque us-
ing the special wrench (see instructions in the
engine user and maintenance manual).
When assembling a new
spark plug, tighten by 1/2 turn after the spark
plug has compressed the sealing washer.
If you put back the old plug after having re-
moved it, tighten it by 1/4 turn after it has
compressed the sealing washer.
The spark plug must be
tightened firmly. A badly positioned spark
plug may become very hot and damage the
engine.
23


Need help? Post your question in this forum.

Forumrules
1

Forum

telair-energy-2510b

Reset search

  • Hello,
    I can not get start on my Telair Energy 2510b. It seems to me that the fuel do not reach the "engine".
    Fuel pump?

    Det ser ikke ut som bensinen suges fra bensintanken. Kan dette være årsaken og evnt.hva må gjøres?
    Jeg tatt service, skiftet olje, skiftet tennplugg og rengjort luftfilter.

    mvh
    Thor, +4795972210
    thor@jemtland.no

    Submitted on 8-7-2022 at 08:48

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 2510b at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 2510b in the language / languages: English as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info