723156
6
Zoom out
Zoom in
Previous page
1/28
Next page
3
EN
Fitting the elements on to the appliance
Clip the end of the hose to the suction inlet - fig. 1.
To remove it, unclip the end and pull - fig. 2.
If your vacuum cleaner is equipped with the telescopic tube* (28): press the adjustment button, extend the length
of tube required and then release the button to lock it - fig. 3. Otherwise, assemble the tubes* (29) by turning
them slightly - fig. 4.
Fit the required accessory on to the end of the tube:
- For rugs and carpets: use the multi-surface nozzle (23) in the retracted brush position - fig. 5, or the mini Turbo-
brush* (26).
- For parquets and smooth floors: use the multi-surface nozzle (23) in the extended brush position - fig. 6 or, for
best results, directly use the parquet nozzle* (25).
- For corners and hard-to-reach areas: use the crevice nozzle (22).
- For furniture and fragile surfaces: use the upholstery nozzle* (24).
Warning! Always switch off and unplug your vacuum cleaner before changing the accessories
Plugging in the power cord and switching on the appliance
Unwind the power cord completely, plug in your vacuum cleaner - fig. 7 and press the ON/OFF pedal (13) - fig. 8.
Adjust the suction power:
- with the electronic power control* (14): turn the electronic control button* to adjust the suction power: towards
the max position for floors and to the min position for furniture and delicate fabrics - fig. 9.
- with the grip's manual power control: open the shutter of the adjustable slider to manually decrease the suction
power, e.g.: on fragile surfaces etc. - fig. 10.
Storing and transporting the appliance
After use, switch off your vacuum cleaner by pressing the ON/OFF pedal (13) - fig. 8 - and unplug it - fig. 11.
Rewind the power cord by pressing the power cord rewind pedal (15) - fig. 12.
• Place the crevice tool (22) in its storage compartment (21) behind the appliance.
Place the multi-surface nozzle (23) in the self-standing position - fig. 13.
Your vacuum cleaner can be easily moved thanks to its transport handle (1).
Important: Always switch off and unplug your vacuum cleaner before carrying out maintenance or cleaning.
Changing the bag
The full bag warning light (12) indicates that the bag is full or saturated.
If you notice a reduction in the efficiency of your appliance, set the power at maximum and hold the nozzle above
the ground. If the full-bag warning light remains red, replace the bag.
Remove the flexible pipe (27) from the suction inlet (11) - fig. 2.
Open the lid (10) of your vacuum cleaner - fig.14.
a) If your vacuum cleaner is equipped with a paper bag*:
remove the bag base (6) from the bag compartment (3) - fig. 15, and then remove the paper bag (7) from its
base (6) by sliding it on the runners - fig. 16;
throw the paper bag in a dustbin - fig.17;
put a new paper bag on the bag base - fig. 18, and then using the bag base runner (5), place it inside the com-
partment - fig. 19;
5. CLEANING AND MAINTENANCE
4. USE
* Model dependent: these parts are specific to certain models or they are accessories that can be purchased separately.
TE_TW22_903690-02_micro-space_903690/02 10/03/15 14:10 Page3
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tefal TW2241 - Micro Space at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tefal TW2241 - Micro Space in the language / languages: English as an attachment in your email.

The manual is 1,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info