. WORD/VIDEO IN connectors
This BNC-type connector is for input of a word clock
signal (44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz,
192 kHz) or a video reference signal (NTSC/PAL black
burst signal, HDTV Tri-Level signal). Use the switch to
set whether or not to terminate with 75Ω.
/ WORD/VIDEO THRU/WORD OUT connectors
This BNC-type connector is for output of a word clock
signal (thru, 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4
kHz, 192 kHz) or a video reference signal (IN connector
signal thru only).
Use the THRU/WORD OUT switch to set the signal
output.
! 75Ω OFF/ON and THRU/WORD OUT switch
Use this switch to make the following settings.
Whether or not the WORD/VIDEO IN connector has
a terminator (75Ω)
The WORD/VIDEO output THRU/OUT setting (OUT
is only for WORD)
@ ETHERNET connector
Use this Ethernet connector to connect to a network
for file transfer and to control this unit from an external
source.
# GROUND terminal
When using a TASCAM RC-HS20PD remote control
(sold separately), depending on the operating
environment, the color display might flicker or noise
might be heard when monitoring. If this occurs, use
the GROUND terminal. (Please prepare a wire to use
with the GROUND terminal.)
PARALLEL connector
The PARALLEL connector on the rear panel allows
external control of this unit. (TASCAM RC-SS20 can be
connected.) The pin assignments are as follows.
Pin No. Normal
RC-SS20
PonMode
I/O
1 GND GND
2 PLAY FLASH 1 I
3 STOP FLASH 2 I
4 RECORD FLASH 3 I
5 SKIP FWD FLASH 4 I
6 SKIP BWD FLASH 5 I
7 (Reserved) STOP I
8 FADER_START FADER_START I
9 (Reserved) (Reserved) O
10 TALLY_PAUSE TALLY_PAUSE O
11 TALLY_RECORD RESERVED O
12 TALLY_STOP TALLY_STOP O
13 TALLY_PLAY TALLY_PLAY O
14
REMOTE_SELECT,
H or Open
REMOTE_SELECT, L I
15 PAUSE FLASH 6 I
16 (Reserved) FLASH 7 I
17 AUX1, FF FLASH 8 I
18 AUX2, REW FLASH 9 I
19 AUX3, MARK FLASH 10 I
20 (Reserved) FLASH_PAGE I
21 (Reserved) (Reserved) O
22 TALLY_SD TALLY_SD*1 O
23 (Reserved) (Reserved) O
24 TALLY_CF TALLY_CF*2 O
25 +5V*3 +5V*3
I: Command input for transport control
Internal circuit, +5V pull-up
Triggers from a low input level of 50 msec or more
O: Command output, for tally output
The internal circuit is open collector (10Ω output
impedance)
Output level low when asserted
20 V dielectric strength, 35 mA maximum current
*1 Assigned to CF indicators when connected RC-SS20
*2 Assigned to CD indicators when connected RC-SS20
*3 +5V: 50 mA maximum supplied current
2−Names and functions of parts
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tascam HS-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tascam HS-2 in the language / languages: English as an attachment in your email.

The manual is 4,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info