32 TASCAM CD-RW901MKII
5 − Recording
Continuous recording (CONT REC)
Using two CD-RW901MKII units to make continuous recording.
1 Connect two CD-RW901MKII units using the
PARALLEL ports.
Unit 1 Unit 2
EOM TALLY (pin 5) FADER START/STOP
(pin 11)
FADER START/STOP
(pin 11)
EOM TALLY (pin 5)
GND (pin 8) GND (pin 8)
2 On both units, select the CONT REC sub-menu in
the REC option (see “Operation basics” on page 16).
Cont Rec> XXX appears on the display where
XXX shows time setting of 30s, 60s or 90s to trigger
the units to start recording when the EOM (End of
Message) tally signal is received one after another.
NOTE
OFF is also shown in the time setting, however if
selected, the CONT REC function is canceled.
We recommend selecting the same time setting on
both units.
The CD-RW901MKII may take longer for OPC calibra-
tion for discs with scratches, grime or dust. To avoid
clipping a recording, we recommend not to use such
discs, or to select a time setting more than 30s.
3 Connect recording source(s) to both units.
4 Press REC key on the one of the units to start
continuous recording, and Cont Rec lights up in
the display.
While the one unit is recording, the second unit
should be in stop mode.
When the remaining time on a disc being recorded
reaches the time setting, the unit sends the EOM
tally signal to the second unit.
Simultaneously, Now OPC is displayed on the second
unit, and when OPC calibration completes, the unit
starts recording.
The two units are now in recording mode during
the time setting selected.
When the first unit finishes recording, the recorded disc
should be replaced with another recordable disc for the
next recording which starts when the unit receives the EOM
tally signal from the second unit. This loop recording will be
continued until either of the units is stopped.
NOTE
While the first unit is recording, the second unit can
be set in recording standby mode. However, it may
shorten the unit’s lifetime by running the motor
continuously. We recommend to set the second unit in
stop mode during stand by.
If the number of tracks is restricted, the EOM tally
signal is not output and the continuous recording
cannot be operated.
The CONT REC function remains selected even the
power is turned off, so that when the power is turned
on again on one of the units, and when the following
conditions are met, the unit starts recording:
Both units are connected
The unit has a recordable disc
To avoid recording accidently, remove the recordable
disc from the unit before turning off the power, or
disconnect the units from each other.
Use two CD-RW901MKII units connected only when
CONT REC is operated. In any other operation, two
units should be disconnected, or set the CONT REC
function off on both units to avoid any unexpected
recording.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tascam CD-RW901MKII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tascam CD-RW901MKII in the language / languages: English as an attachment in your email.

The manual is 2,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info